CMRR: 120 dB
NMRR: 60 dB
Width: 96 mm
Height: 48 mm
Length: 127 mm
Weight: 295 g
Accuracy: ± 0.5 °C
Polarity: Unipolar
Approvals: UL, C-UL, UKCA, CE per 2014/35/EU
Frequency: 50 to 400 Hz
Isolation: Power to Input/Output: 2300 Vac per 1 minute test For Low Voltage Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Output: 2300 Vac per 1 minute test Relay/SSR to Relay/SSR Output: 2300 Vac per 1 minute test RS232/485 to Input/Output: 500 Vac per 1 minute test
Input Type: Thermocouple, RTD, Voltage, Current
Resolution: Temperature :1° /0.1° ; process : 10 µV
input-type: Thermocouple, RTD, Voltage, Current
Form factor: 1/8 DIN
Display Type: 4 Digit LED
Reading Rate: 3/sec
Accuracy Note: ±0.5°C temp nominal; 0.03% rdg ±0.03% range process and strain (@25 °C );"Universal Temperature/Process Input Models;Thermocouple Accuracy:;Type J: 0.4°C (0.7°F);Type K: 1.0°C (1.8°F) and 0.4°C (0.7°F);Type T: 1.0°C (1.8°F) and 0.4°C (0.7°F);Type E: 1.0°C (1.8°F) and 0.4°C (0.7°F);Type R: 1.0°C (1.8°F) and 0.5°C (0.9°F);Type S: 1.0°C (1.8°F) and 0.5°C (0.9°F);Type B: 1.0°C (1.8°F) and 0.5°C (0.9°F);Type C: 0.4°C (0.7°F);Type N: -1.0°C (1.8°F) and 0.4°C (0.7°F);Type L: 0.4°C (0.7°F);RTD Accuracy;Pt, 0.00385, 100 ohm: ±0.5°C ±.02% rdg;Pt, 0.00385, 500 ohm: ±0.6°C ±.02% rdg;Pt, 0.00385, 1000 ohm: ±0.5°C ±.02% rdg;Pt, 0.00392, 100 ohm: ±0.5°C ±.02% rdg ;Pt, 0.00392, 500 ohm: ±0.5°C ±.02% rdg;(Nickel MIL-T-7990B) (FS required): 0.1°C (0.2°F);(Nickel MIL-T-7990B) (FS required): 0.3°C (0.5°F);Process Voltage Accuracy: 0.03% rdg;Process Current Accuracy: 0.03% rdg
Configuration: Single-ended
Display Range: -1999 to 9999
Input Current: 0 to 20 mA (5 Ω load)
Input Voltage: 0 to 100 mV, 0 to 1V, 0 to 10 Vdc
Output Detail: Relay: 250 Vac or 30 Vdc @ 3 A (resistive load); configurable for on/off, PID, and ramp and soak Output 1: SPDT, can be configured as an alarm 1 output Output 2: SPDT, can be configured as an alarm 2 output SSR: 20 to 265 Vac @ 0.05 to 0.5 A (resistive load); continuous DC Pulse: Non-isolated; 10 Vdc @ 20 mA Analog Output (Output 1 Only): Non-isolated, proportional 0 to 10 Vdc or 0 to 20 mA; 500 Ω max Output 3 Retransmission Isolated Analog Voltage and Current Current: 10 V max @ 20 mA output Voltage: 20 mA max for 0 to 10 V output
Sampling Rate: 3 Hz (3 updates/second)
Step Response: 0.7 sec for 99.9%
A/D Conversion: Dual slope
Control Action: Action: Reverse (heat) or direct (cool)
Control Output: SPDT Relay, Alarm
Data Interface: RS485, RS422, RS232, Modbus RTU, Modbus ASCII
Digital Filter: Programmable
Supply Voltage: 90 to 240 Vac
Impedance Input: 10 MΩ for 100 mV ;1 MΩ for 1 or 10 Vdc
Measuring Range: Universal Temperature/Process Input Models;Thermocouple: Type J: -210 to 760 °C;Type K: -270 to -160 °C and -160 to 1372 °C;Type T: -270 to -190 °C and -190 to 400 °C;Type E: -270 to -220 °C and -220 to 1000 °C;Type R: -50 to 40 °C and 40 to 1768 °C;Type S: -50 to 100 °C and 100 to 1768 °C;Type B: 100 to 640 °C and 640 to 1820 °C;Type C: 0 to 2320 °C;Type N: -250 to -100 °C and -100 to 1300 °C;Type L: -200 to 900 °C;RTD;Pt, 0.00385, 100 ohm: -200 to 850 °C;Pt, 0.00385, 500 ohm: -200 to 850 °C;Pt, 0.00385, 1000 ohm: -200 to 850 °C;Pt, 0.00392, 100 ohm: -200 to 850 °C ;Pt, 0.00392, 500 ohm: -200 to 850 °C;(Nickel MIL-T-7990B) (FS required): 0 to 200 °C;(Nickel MIL-T-7990B) (FS required): -40 to 300 °C ;Process Voltage: 0 to 100 mV, 0 to 1V, +100 mV, 0 to 10V;Process Current: 0 to 20 mA (4 to 20 mA)
Span Adjustment: 0.001 to 9999 counts
Thermal Effects: -1999 to 9999
Number of Inputs: 1
Cutout Dimensions: 45 mm
Decimal Selection: 3-Position
Enclosure Ratings: NEMA Type 1
Relative Humidity: 0.9
Supply Power Note: 90 to 240 Vac ±10%, 50 to 400 Hz*, 110 to 300 Vdc, equivalent voltage
Supply Power Type: AC
Data Interface Note: RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status Supported Protocols: TCP/IP, ARP, HTTPGET RS485: Addressable from 0 to 201
Linearization Points: Up to 10
Additional Features 1: Programmable 3 Color Display
Electrical Connection: Screw Terminal
Retransmission Output: N/A
Temperature Stability: RTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C
Sensor/Transmitter Power: 24 Vdc @ 25 mA
Operating Temperature Note: 0 to 55°C (32 to 131°F) 90% RH non-condensing
Operating Temperature, Max: 55 °C
Operating Temperature, Min: 0 °C
Sensor/Transmitter Power Note: 5 Vdc @ 40 mA; 10 Vdc @ 60 mA (Optional In Place Of Communication)
Thermocouple Lead Resistance, Max: 100 Ω