System controller: Integrated controller with 8 Core Intel Xeon processors,Intel Xeon

Operating system: Windows 10 (64-bit)

Test Development Environment

User interface: Microsoft Windows based software solution with easy-to-use GUI and password-protected user levels

Off-line test development software: Optional for off-line PC

CAD conversion tool: Support 4 different types of CAD in V810i software and optional software available to translate other CAD data to ViTrox's format

Typical test development time: 4 hours to 1.5 days to convert raw CAD file and develop application

Line Integration

Transport heights: 880mm - 950mm

Line communication standard: SMEMA, HERMES

Barcode readers: Compatible with most industry standard barcode readers

Performance Parameters

False Call rate: 500 - 1000ppm

Minimum features detection capability

Joint pitch¹: 0.1mm and above

Short width²: 0.015mm

Solder thickness: 0.0127mm

Allowable Panel Characteristics: Standard

Maximum PCB Size (L x W):

50°: 800mm x 600mm (31.4" x 23.6")

30°: 1015mm x 600mm (39.9" x 23.6")

Minimum PCB Size (L x W): 50mm x 50mm (2” x 2”)

Maximum PCB inspectable area:

Single Stage:

50°: 400mm X 594mm (15.7" x 23.3")

30°: 650mm X 594mm (25.5" x 23.3")

Dual Stage (Long Board):

50°: 800mm X 594mm (31.4" x 23.3")

30°: 1015mm X 594mm (39.9" x 23.3")

Nominal Pixel Range: *2μm#, 4um, 8μm, 15μm, 22μm, 30μm

Maximum PCB thickness: 15mm (590mils)

Minimum PCB thickness: 0.508mm (20mils)

PCB warp: Downward < 3mm; Upward < 3mm

Maximum PCB weight: 15kg (25kg Optional)

Top Clearance of PCB: 10mm - 90mm (Inclusive board thickness)

Bottom Clearance of PCB: 130mm

PCB edge clearance: 3mm

100% Press-fit testability Yes (With PSP2 / PSP2.1 feature)

PCB Temperature: 40⁰C

Safety Standards: X-ray radiation leakage is below 0.5 µSv/hr

Installation Specification

Power Supplies: 200 – 240 VAC three phase; 380 – 415 VAC three phase wye (+/- 5) (50Hz or 60Hz)

Air requirement: 552kPA (80psi) compressed air

System footprint (Width X Depth X Height): 1878mm x 2430mm x 2425mm

Total system weight:  ~6000kgs