Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Power supply: Rechargeable lithium-ion battery packs 9.6V, backup charger.
Battery indicator: Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power consumption: Current consumption of normal test 490 mA, continuous working for 8 hours.
Display mode: LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
Size of clamp
008 small sharp current clamp: 7.5mm×13mm;
040circle current clamp: 35mm×40mm;
068Bcircle current clamp: 68mm×68mm.
300F Flexible Coil Current Sensor (with Integrator) : Ф300mm
Instrument dimensions L×W×H: 240mm×170mm×68 mm.
Number of channels: 4U/4I.
Phase-to phase voltage: 1.0V~2000V.
Phase-to-neutral voltage: 1.0V~1000V.
Current
008B current clamp: 10mA~10.0A;
040B current clamp: 0.10A~100A;
068B current clamp: 1.0A~1000A;
300F Flexible Coil Current Sensor (with Integrator) : 10A ~ 3000A
Frequency: 40Hz~70Hz.
Parameters of electricity: W, VA, Var, PF, DPF, cosφ, tanφ.
Energy parameters: Wh, Varh, Vah.
Harmonic: Order 0~50.
Total harmonic distortion: Order 0~50, each phase.
Expert mode: Yes.
Number of Transient records 150 sets.
Voltage flicker Yes.
Starting current mode: Yes, 100 seconds.
3 phases unbalance: Yes.
Record: 300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded value: Measurement of maximum and minimum values over a period of time.
Alarm: 40 different types of parameter selections, 12,800 sets alarm logs.
Peak: Yes.
Phasor diagram display: Automatically.
Capacity of snapshots: 60.
Menu language: English/Chinese.
Communication: USB.
Automatic switching off
When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress,the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight function: Yes, suitable for use at night and dark place.
Weight Host: 1.6kg (with battery).
008B small sharp current clamp: 170g×4;
040Bcircle current clamp: 190g×4;
068Bcircle current clamp: 510g×4;
300F Flexible Coil Current Sensor (with Integrator) : 330g×4;
Test wires and power adapter: 900g;
Total weight: about 9.2kg (with packaging).
Length of voltage test wire: 3m.
Length of current sensor wire: 2m.
Working temperature and humidity: -10°C~40°C; below 80%Rh.
Storage temperature and humidity: -10°C~60°C; below 70%Rh.
Input impedance Input impedance of test voltage:1MΩ.
Withstand voltage: Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
Insulation: Between instrument wiring and shell ≥10MΩ.
Structure: Double insulation, with insulation vibration-proof sheath.
Safely rules: IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.