Measurement parameters: Insulation Resistance and Leakage Current
Output voltage: 1V~1000V (DC)
Voltage accuracy:
≥10V, ±1%+1V
<10V, ±10%+0.1V
Measurement range: 10kΩ~10TΩ
Measurement accuracy: <1M: 5%;≥1M: 1% ; ≥1G: 3% ;≥10G: 5% ; ≥1T: 10%
Test speed: Fast: 30ms/time, medium: 100ms/time, slow: 500ms/time
Range modeL: Automatic, locking, sorting
Maximum charging current: 25mA±5mA
Show results: Voltage, current, resistance, sorting results, sound and light alarm
Trigger mode: Internal , manual , external and remote
Charging time: 0~999s, programmable
Testing time: 0~999s, programmable
Discharge time: 0~999s, programmable
File management: 100 test files
Comparator function: yes
U disk data recording: yes
Contact check: yes
Display: 4.3inch TFT-LCD
Protocol: SCPI, Modbus RTU
Interface: RS232C,USB HOST,HANDLER,FOOT, LAN,RS485(optional)