Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

- VOLTAGE/CURRENT LEVELS
Voltage Range: Range 1 - 0V to 50V
Range 2 - 0V to 80V
Current Range: 10mA to 50A
Power Range: Up to 750W
- OUTPUT SETTING
Operating Mode: Constant voltage, constant current or constant power with automatic cross-over dependent on output setting parameters CV, CC or CP mode indication in display
Voltage Setting: Resolution- 1mV for 50V range, (2mV for 80V range)
Current Setting: Resolution 10mA
Setting Accuracy: Voltage- 0.1% ± 2mV on 50V range, (0.1% ± 4mV on 80V range)
Current - 0.3% ± 20mA
- OUTPUT PERFORMANCE
Load regulation: <0.01% +5mV (CV mode) for any load change within the PowerFlex envelope,using remote sense.
Line regulation: <0.01% +5mV for a 10% line voltage change.
Ripple & Noise: (20MHz bandwidth): Typically <3mV rms, <20mV pk-pk.
Transient Response: To within 100mV of set level for a 5% to 95% load change.
Rear Terminals: <2ms
Front Terminals: <2.5ms
Sensing: Selectable local or remote sensing.
Output Protection: Output will withstand forward voltages of up to 90V
Reverse protection by diode clamp
Over Voltage protection (OVP): Settable 2V to 90V in 0.1V steps
Over Current protection (OCP): Settable 2A to 55A in 0.1A steps
- METER SPECIFICATIONS
Display Type: 4.3 inch (10.9 cm) backlit TFT LCD, 480x272 pixels total, 16 colours, resistive touch screen.
Meter Function: 5 digit voltage meter and 4 digit current meter. Display of limits values,memory contents etc. Wide range of alpha-numeric messages/menus.
Limits Display: Limits settings can be displayed simultaneously with measurements.
Meter Resolution: Voltage- 1mV (2mV on 80V range). Current- 10mA.
Meter Accuracy: Voltage: 0.1% of reading ± 2 digits.
Current: 0.3% of reading ± 2 digits.
- GENERAL SPECIFICATIONS
AC Input: 110V to 240V AC ±10%, 50/60Hz. Installation Category II.
Input Power: 1000VA Max.
Temperature: Operating: +5ºC to +40ºC, 20% to 80% RH, Storage: -40ºC to + 70ºC.
Safety: Complies with EN61010-1.
EMC: Complies with EN61326.
Size: 215 x 130 x 460mm (WxHxD) (3U High) Including terminals
Weight: <6.4kg (14lb)