Bandwidth: DC to ≥120 MHz
Rise time: ≤2.92 ns
Maximum DC current: 30 A
Maximum RMS current: 30 A
Maximum peak pulse current: 50 A
Maximum bare wire voltage: 150 V CAT II, (insulated wire 300 V CAT II)
Sensitivity: 1 mA (on oscilloscopes that support 1 mV/div setting)
DC accuracy: ±3% warranted
Accuracy, typical
DC: ±1% of reading
DC to 60 Hz, ≤5 A: ±1%
60 Hz – 5 kHz, ≤5 A: ±1.5%
DC – 5 kHz, >5 A: ±1.5%
Maximum Amp-Second product: 500 A*µs (in 30 A range)
Insertion impedance
1 mΩ at 10 kHz
3.5 mΩ at 100 kHz
0.08 Ω at 1 MHz
0.15 Ω at 10 MHz
0.7 Ω at 100 MHz
0.85 Ω at 120 MHz
Signal delay: 14.5 ns
Current ranges: 5 A and 30 A
Power requirements: TCP0030A is powered directly by oscilloscopes with the TekVPI™ interface.
Include: TCP0030A R5