Test Index: Moisture, Ash, Volatile Matter and LOI
Continuous Test in Batches: Yes
Standards: ISO 17246, ISO 18123/18122/18134, ISO 11722, ISO 1171, ISO 562, ASTM D3173/D3174/D3175/D7582, GB/T 30732, GB/T 212
Precision: 0.02% RSD
Furnace: Dual furnaces, one for moisture and ash, one for volatile matter
Furnace Temperature: Room temperature~1000℃
Temperature Control Precision: ±2℃
Temperature Resolution: 0.1℃
Reproducibility: Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%); Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)
Cooling Time Required for Batches of Test: No
Furnace Cooling (forced air/N2): 950 to 500°C <30 min
Balance Resolution: 0.0001g
Sample Introduction and Taking: Automatic
Max. Samples: 19 samples + 1 blank sample position (Moisture & Ash); 25 samples + 1 blank sample position (Volatile matter)
Quantity of Sample / Test Time: Full indexes for 19 samples <120 min (Quick method)
Sample Weight: 0.5 up to 5g
Max. Power: 4kW for moisture/ash testing; 2.5kW for volatile matter testing
Interface: RS232
Furnace Heating: Resistance Wound
Temperature Calibration: Standard thermocouple
Temp. Control Precision: ±2℃ (moisture), ±5℃ (ash, volatile matter)
Gas Flow Rate: GB: Moisture: Nitrogen, 30~60 times/h; Ash: Air 60~120 times/h; ASTM: Moisture: Nitrogen or Air 2~4 (Furnace Volume/min); Volatile matter: Nitrogen 2~4 (Furnace Volume/min)
Power Requirement: AC 220V (±10%), 50/60Hz
Gas Requirement: Nitrogen/Oxygen/Compressed Air
Gas Pressure: Air 5 to 6 bar (75 to 90 psi)
Minimum Gas Purity: Air/Nitrogen/Oxygen 99.5%; dry, oil-free
Sample Weighing: Under normal temperature
Test Temperature: Moisture 105℃, Ash 815℃, Volatile matter 920℃~950℃ (Can be customized)
Humidity: <80%
Dimensions: Moisture & Ash Analyzer: 550x590x530mm; Volatile Matter Analyzer: 550x650x815mm
Weight: Moisture & Ash Analyzer: 70kg; Volatile Matter Analyzer: 95kg
Operational Control: Windows®-based software on external PC / Windows7 / WindowsXP
Advance Calculation: Yes
Analysis Report: Yes
Statistics Report: Yes
System Monitor: Yes