PV voltage range: 0–1000 V
Current range: 0-20 A (30A option also available)
Voltage accuracy (0 to 55°C): ±0.5% ± 0.25 V
Current accuracy (0 to 55°C): ±0.5% ± 0.04 A
Voltage resolution: 25 mV
Current resolution: 2 mA
Measurement duration: 4s (typical, from ‘Measure Now’ to returned I-V trace)
I-V sweep duration: 0.05 - 2s. Typically 0.2s for PI/ strings.
I-V trace points: 100 or 500, user selectable
Operating temp range: -10 to +65°C
Battery life: 12 hr continuous operation, more than 1000 I-V curves.
Protection features: Over-voltage, -current, -temperature, and reverse polarity
PVA-1000S Includes:
• I-V Measurement Unit with shoulder strap
• PVA Software for Windows™
• Wireless USB Interface for Windows™ laptop or tablet
• Connector savers, MC-4 to MC-3 adaptors, MC-4 connector tool
• Battery charger (AC adapter)
• Short USB extension cable