Display: 7 inch TFT Touch Screen (800×480)
Connectivity: USB×2; 10/100Mbit/s RJ-45×1
Memory: 2GB
Power Supply: Rechargeable Li-Ion Battery/AC Adapter
Battery Life: 10 hours continuous operation
Working Temp.: -20°C - 50°C
Storage Temp.: -40°C - 60°C
Humidity: 0 - 95% (Non-Condensing)
Weight: 2.1kg
Dimensions (L×W×H ): 290×175×75mm
OTDR Module: Wavelength
MTP-200-D100: 1528.77-1566.72nm @ 0.4nm Spacing
Dynamic Range(1): 38dB
Dead Zone(2): EDZ: 1m, ADZ: 4m
Selectable Range: SM: 1.3, 2.5, 5, 10, 20, 40, 80, 160, 240Km
Pulse Width: SM: 5ns,10ns, 30ns, 100ns, 300ns,1µs, 2.5µs,10µs, 20µs
Sampling Points: 256000
Averaging Time: Quick, 15s, 30s, 45s, 60s, 90s, 120s, 180s
Connector: FC/PC (Interchangeable SC, ST and LC )
Distance Accuracy: ±(1m + 5x10-5 x distance +sampling resolution)
Attenuation Accuracy: ±0.05 dB/dB
Reflection Accuracy: ±4 dB
Visible Laser Source: Output Power: ≥ -3dBm; MOD Frequency: 1Hz; Detecting Range: 5Km
Tunable Laser Source:
Frequency Range: 191 - 196 THz
Wavelength Range: 1528-1566nm
Accuracy: 2.5 GHz
Line Width: 10 MHz
SMSR: 40 dB
Output Power Range: +9 dBm to +13 dBm (C Band)
Power Setting Resolution: 0.01 dB
Power Variation over Wavelength Range: ±0.5 dB
Minimum Channel Spacing: 50 GHz (0.4nm)
Reflection Accuracy: ±4 dB
Relative Intensity Noise: -140 dB/Hz
MCI100 Optical Connector Inspector Module (Optional):
Field of View: 400µm×300µm
Resolution: ≤1.5µm
Focusing: Manual Focus
Microscope Dimensions: Ø32×175mm
PM100 Normal Power Meter Module (Optional):
Calibrated Wavelength: 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, 1650nm
Measurement Range: -70dBm - +6dBm (-60dBm - +6dBm @ 850nm)
Detector Type: InGaAs
Display Resolution: 0.01dB
Accuracy: ± 5% ± 0.01nW (±0.5dB@850nm)
*Specifications subject to change without notice.
Notes
(1) Dynamic range measurement at 20µs pulse width and 180s averaging time;
(2) Dead Zone measurement at 0.6Km and reflection <-45dB; EDZ measurement at 5ns, ADZ measurement at 10ns.
Order Information:
Standard Package
MTP-200, Lithium Battery, CD (User’s Manual and MTP Suite Software), Carrying Case, Warranty card, Calibration Certificate