Rigel medical PatSim 400 Patient Simulator (60bpm or 240bpm)

ModelPatSim 400
P/N404A940
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Simulation Type

Lead I: 70%

Lead II: 100%

Lead III: 30%

Lead V1: 24%

Lead V2: 48%

Lead V3: 100%

Lead V4: 120%

Lead V5: 112%

Lead V6: 80%

ECG Performance Tests

Square Waves: 2Hz, 0.125Hz

Triangle Wave: 2Hz

Pulse: 60bpm or 240bpm

Sine Waves: 0.05, 0.5, 1, 10, 25, 30, 40, 50, 60, and 100Hz

Performance Amplitude: 0.5 to 5.0mV in 0.5mV steps

Arrhythmias

Ventricular:

Asystole

Bigeminy

Trigeminy

Ventricular fibrillation (coarse)

Ventricular fibrillation (fine)

Ventricular tachycardia

Supraventricular:

Atrial fibrillation (coarse)

Atrial fibrillation (fine)

Atrial flutter

Atrial tachycardia

Missing beat

Nodal rhythm

Paroxysmal atrial tachycardia

Sinus arrhythmia

Supraventricular tachycardia

Atrial Conduction:

First degree AV block

Left bundle branch block

Right bundle branch block

Second degree AV block - Mobitz I

Second degree AV block - Mobitz II

Third degree AV block

Premature:

Premature atrial contraction

Premature nodal contraction

Premature left ventricle contraction

Premature left ventricle contraction - early

Premature left ventricle contraction - R on T

Premature right ventricle contraction

Premature right ventricle contraction - early

Premature right ventricle contraction - R on T

Premature ventricular contraction - 6 / min

Premature ventricular contraction - 12 / min

Premature ventricular contraction - 24 / min

Premature ventricular contraction - frequent multifocal


Invasive Blood Pressure

Channels: 4 channels

Static Pressure: -10, -5, 0, 20, 40, 50, 60, 80, 100, 150, 160, 200, 240, 320, 400mmHg

Dynamic Simulation:

Arterial [ART]: 120/80

Radial Artery [RA]: 120/80

Left Ventricle [LV]: 120/00

Right Ventricle [RV]: 25/00

Right Atrium (central venous) [CVP]: 15/10

Pulmonary Artery [PA]: 25/10

Pulmonary Artery Wedge [PAW]: 10/2

Left Atrium [LA]: 14/4

Accuracy: ± 1mmHg

Excitation Voltage: 2 to 16V

Impedance: 350Ω Nominal

Simulated Sensitivity: 5μV/V/mmHg or 40μV/V/mmHg (user selectable)

Connector: Mini DIN style


Respiration

Rates: Selectable values of 0, 5, 10, 15, 30, 40, 60, 80, 120, 180 brpm

Lead Selection: Lead I and II, user selectable

Base Resistances: 500, 1000, 1500 & 2000Ω

Accuracy: ±10%

Resistance Variations: 0.2, 0.5, 1.0, 3.0Ω

Apnoea Simulation: Manual ON / OFF


ECG

Normal Sinus Rhythm:

Rates: 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM

Rate Accuracy: ±1BPM or 1%

Amplitude (Lead II): 0.05 to 0.45mV (0.05mV steps), 0.5 to 5.5mV (0.5mV steps)

Amplitude Accuracy: ± 2%

ST Segments: 18 selectable values, 8 elevated and 8 depressed -0.8 to +0.8mV in 0.1mV steps and +0.05mV and -0.05mV on Lead II

Neonatal Mode: ECG R wave width is reduced to 40ms


Pacemaker

Simulated Rhythms:

Asynchronous at 75 BPM

Demand with frequent sinus beat

Demand with occasional sinus beat

A-V sequential

Non-capture

Non-function

Pulse Amplitude: 1.0, 2.0, 5.0, 10.0mV

Accuracy: ± 5%

Width: 0.1, 0.2, 0.5, 1.0, 2.0ms

R-Wave Detector Test: 30, 60, 80, 120, 200, 250 BPM

Haver-Triangle Width: 8, 10, 12, 20, 40, 60, 80, 100, 120, 140, 160, 180, 200ms

Performance Amplitude: 0.5 to 5.0mV in 0.5mV steps


Fetal Simulation

Maternal Heart Rate: 80 BPM (Fixed)

Fetal Heart Rate (Selectable): 60, 90, 120, 140, 150, 210, 240 BPM

Fetal Heart Rate (IUP): 140 BPM at beginning, then varying with pressure

Intrauterine-Pressure Waveforms: Early deceleration, late deceleration, and uniform acceleration

Simulation Period: Manual, or 2, 3, or 5 minutes


Temperature

Simulation: YSI 400 / 700A / 700B Static

Temperature Unit: °C or °F, user selectable

Range: 0.0, 24.0, 37.0, and 40.0°C; 32.0, 75.2, 98.6, 104.0°F

Accuracy: ± 0.1°C / °F

Connector: Mini DIN style


Mains Power/Battery Info

Battery: 3.7V 3900mAh 14.4WH

Power Supply: 5V 1A USB micro-B

Input Voltage: 100-240V ~ 50/60Hz 0.18A max.

Charge Time (new battery): Up to 3-4 hours

Battery Life: Up to 6 hours, ~4 hours

Weight: 0.70kg / 1.5lbs

Dimensions: 180 x 150 x 55mm, 7.1 x 5.9 x 2.2"


Cardiac Output

Catheter Type: Baxter Edwards, 93a-131-7f

Calibration Coefficient: 0.542 (0 °C injectate), 0.595 (24 °C injectate)

Blood Temperature: 37 °C (98.6 °F) ± 2 %

Injectate Volume: 10 cc

Injectate Temperature: 0 °C or 24 °C ± 2 % value

Cardiac Output: 2.5 l/min, 5 l/min, 10 l/min ± 5 %

Connector: Mini DIN style