For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.TH
0
Product image

Rigel medical PatSim 200 Patient Simulator (60bpm or 240bpm)

ModelPatSim 200
P/N404A920
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Simulation Type

Lead I: 70%

Lead II: 100%

Lead III: 30%

Lead V1: 24%

Lead V2: 48%

Lead V3: 100%

Lead V4: 120%

Lead V5: 112%

Lead V6: 80%


ECG Performance Tests

Square Waves: 2Hz, 0.125Hz

Triangle Wave: 2Hz

Pulse: 60bpm or 240bpm

Sine Waves: 0.05, 0.5, 1, 10, 25, 30, 40, 50, 60, and 100Hz

Performance Amplitude: 0.5 to 5.0mV in 0.5mV steps


Arrhythmias

Ventricular: Asystole, Bigeminy, Trigeminy, Ventricular fibrillation (coarse), Ventricular fibrillation (fine), Ventricular tachycardia

Supraventricular: Atrial fibrillation (coarse), Atrial fibrillation (fine), Atrial flutter, Atrial tachycardia, Missing beat, Nodal rhythm, Paroxysmal atrial tachycardia, Sinus arrhythmia, Supraventricular tachycardia

Atrial Conduction: First degree AV block, Left bundle branch block, Right bundle branch block, Second degree AV block - Mobitz I, Second degree AV block - Mobitz II, Third degree AV block

Premature: Premature atrial contraction, Premature nodal contraction, Premature left ventricle contraction, Premature left ventricle contraction - early, Premature left ventricle contraction - R on T, Premature right ventricle contraction, Premature right ventricle contraction - early, Premature right ventricle contraction - R on T, Premature ventricular contraction - 6 / min, Premature ventricular contraction - 12 / min, Premature ventricular contraction - 24 / min, Premature ventricular contraction - frequent multifocal


Invasive Blood Pressure

Channels: 2 channels

Static Pressure: -10, -5, 0, 20, 40, 50, 60, 80, 100, 150, 160, 200, 240, 320, 400mmHg

Dynamic Simulation: Arterial [ART] 120/80, Radial Artery [RA] 120/80, Left Ventricle [LV] 120/00, Right Ventricle [RV] 25/00, Right Atrium (central venous) [CVP] 15/10, Pulmonary Artery [PA] 25/10, Pulmonary Artery Wedge [PAW] 10/2, Left Atrium [LA] 14/4

Accuracy: ± 1mmHg

Excitation voltage: 2 to 16V

Impedance: 350Ω Nominal

Simulated sensitivity: 5μV/V/mmHg or 40μV/V/mmHg (user selectable)

Connector: mini DIN style


Respiration

Rates: Selectable values of 0, 5, 10, 15, 30, 40, 60, 80, 120, 180 brpm

Lead Selection: Lead I and II, user selectable

Base Resistances: 500, 1000, 1500 & 2000Ω

Accuracy: ±10%

Resistance Variations: 0.2, 0.5, 1.0, 3.0Ω

Apnoea Simulation: Manual ON / OFF


ECG

Normal Sinus Rhythm

Rates: 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM

Rate Accuracy: ±1BPM or 1%

Amplitude (lead II): 0.05 to 0.45mV (0.05mV steps), 0.5 to 5.5mV (0.5mV steps)

Amplitude Accuracy: ± 2%

ST Segments: 18 selectable values, 8 elevated and 8 depressed -0.8 to +0.8mV in 0.1mV steps and +0.05mV and -0.05mV on Lead II

Neonatal Mode: ECG R wave width is reduced to 40ms


Pacemaker

Simulated Rhythms: Asynchronous at 75 BPM, Demand with frequent sinus beat, Demand with occasional sinus beat, A-V sequential, Non-capture, Non-function

Pulse Amplitude: 1.0, 2.0, 5.0, 10.0mV

Accuracy: ± 5%

Width: 0.1, 0.2, 0.5, 1.0, 2.0ms

R-Wave Detector Test: 30, 60, 80, 120, 200, 250 BPM

Haver-Triangle Width: 8, 10, 12, 20, 40, 60, 80, 100, 120, 140, 160, 180, 200ms

Performance Amplitude: 0.5 to 5.0mV in 0.5mV steps


Fetal Simulation

Maternal Heart Rate: 80 BPM (Fixed)

Fetal Heart Rate (Selectable): 60, 90, 120, 140, 150, 210, and 240 BPM

Fetal Heart Rate (IUP): 140 BPM at beginning, then varying with pressure

Intrauterine-Pressure Waveforms: Early deceleration, late deceleration, and uniform acceleration

Simulation Period: Manual, or 2, 3, or 5 minutes


Temperature

Simulation: YSI 400 / 700A / 700B Static

Temperature Unit: °C or °F, user selectable

Range: 0.0, 24.0, 37.0, and 40.0°C, 32.0, 75.2, 98.6, 104.0°F

Accuracy: ± 0.1°C / °F

Connector: Mini DIN style


Mains Power/Battery Info

Mains Power/Battery Info: 3.7V 3900mAh 14.4WH, 5V 1A USB micro-B power supply, 100-240V ~ 50/60Hz 0.18A max.

Charge Time (new battery): Up to 3-4 hours

Battery Life: Up to 6 hours, ~4 hours

Weight: 0.70kg / 1.5lbs

Dimensions: 180 x 150 x 55mm, 7.1 x 5.9 x 2.2"

Datasheet


Manual


Video

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts