R&D Instruments mV / mA Loop Calibrator
ManufacturerR&D Instruments(View more products from this manufacturer)
ModelmV / mA
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available
Application:
Ideal for calibrating indicators, controllers, transmitters,
receivers and mA/mV measuring instruments.
Current Terminal Input
Protection : Fuse: 100mA / 250V
Backlight : LED backlight
Power supply : Li-ion Rechargeable Battery
Low Battery Indicator : Yes
Battery backup : 40 hours @ no load condition
11 hours @ 20mA with 850 ohm load
Loop power supply : 24V ±10%
Operating Temperature : 10 to 50°C
Instrument Casing : ABS Plastic
Instrument Dimensions : 180 mm x 110 mm x 35 mm (LxWxD)
Instrument Weight : 350 gms
MEASURE Mode
mA: Range: 0 to 25; Resolution: 0.001 (mA); Accuracy: ±0.025% of Reading + 10µA
mV: Range: 0 to 200; Resolution: 0.001 (mV); Accuracy: ±0.025% of Reading + 10 µV
SOURCE Mode
mA: Range: 0 to 25; Resolution: 0.001 (mA); Accuracy: ±0.025% of Reading + 10µA
mV: Range: 0 to 200; Resolution: 0.001 (mV); Accuracy: ±0.025% of Reading + 10 µV
Standard Delivery
1. Instrument : 1 no.
2. Carrying Pouch : 1 no.
3. Test Lead (2 wire) : 2 nos.
4. Charger : 1 no.
5. User Manual : 1 no.
6. Traceable Calibration Certificate
Optional:
Accredited (NABL) Calibration Certificate as per ISO/IEC 17025:2005 Standard
Ideal for calibrating indicators, controllers, transmitters,
receivers and mA/mV measuring instruments.
Current Terminal Input
Protection : Fuse: 100mA / 250V
Backlight : LED backlight
Power supply : Li-ion Rechargeable Battery
Low Battery Indicator : Yes
Battery backup : 40 hours @ no load condition
11 hours @ 20mA with 850 ohm load
Loop power supply : 24V ±10%
Operating Temperature : 10 to 50°C
Instrument Casing : ABS Plastic
Instrument Dimensions : 180 mm x 110 mm x 35 mm (LxWxD)
Instrument Weight : 350 gms
MEASURE Mode
mA: Range: 0 to 25; Resolution: 0.001 (mA); Accuracy: ±0.025% of Reading + 10µA
mV: Range: 0 to 200; Resolution: 0.001 (mV); Accuracy: ±0.025% of Reading + 10 µV
SOURCE Mode
mA: Range: 0 to 25; Resolution: 0.001 (mA); Accuracy: ±0.025% of Reading + 10µA
mV: Range: 0 to 200; Resolution: 0.001 (mV); Accuracy: ±0.025% of Reading + 10 µV
Standard Delivery
1. Instrument : 1 no.
2. Carrying Pouch : 1 no.
3. Test Lead (2 wire) : 2 nos.
4. Charger : 1 no.
5. User Manual : 1 no.
6. Traceable Calibration Certificate
Optional:
Accredited (NABL) Calibration Certificate as per ISO/IEC 17025:2005 Standard
Stay Updated with Offers
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Quick Support
Direct access to our certified experts