Sensor Body Dimensions: 77 mm D x 134 mm H (3 in x 5.3 in)
Rear thread 1” BSP/NPT
Weight: 1 kg (2.2 lb)
Measurement range: 125 mm to 3 m (4.9 in to 9.8 ft)
Frequency: 125kHz
Beam Angle: <10°
Effective Beam Angle (using DATEM): 3°
Accuracy: 2 mm (0.08 in)
Resolution: 1 mm (0.04 in)
Housing Material: Valox 357 PBT (Polybutylene terephthalate)
Temperature Compensation: Automatic, internal temperature sensor, ± 0.5 °C/°F
Transducer Cable Requirements: Twin screened. Integral cable length 5 m, 10 m, 20 m or 30 m (16.4 ft, 32.8 ft, 65.6 ft, 98.4 ft)
Operating Temperature Range: 40 °C to +80 °C (-40 °F to +176 °F) process temperature
Ingress Protection: IP68 to BS EN 60068-2-17:1995 and BS EN 60529 (Nema 6P available)
Approvals: See EC Declaration of Conformity in the manual
Hazardous Area Approval: ATEX; Ex ia Zone 0 and FISCO
Power: Bus-powered, per IEC 61158-2; 20mA (general purpose or I.S. version) 20mA 18-24 V DC
Update Time: 1 to 2 seconds at 20mA current loop
Programming: PA modem; Simatic PDM, EDDL, FDT/DTM on request. PC interface 2-wire loop powered from PC or laptop. No external power is required.
Outputs: Profile 3.0.2, Class A with I&M functionality