- Controls: OFF-ON Cut Off Voltage, 10, 50 and 100 Volts (Selects Voltage to stop timing)
- Indicators:
Green LED: Decay Cycle Ready > ±1kV, CPM voltage > ±1,000 Volts
Red LED: Timing in Progress, CPM voltage decay timing activated
LOBAT: Displayed when battery voltage < 6.0 Volts
- Display: Liquid Crystal Display (LCD) displays elapsed decay time from ±1,000 Volts to selected Cut Off voltage in seconds and tenths of a second (00.0)
- Polarity: Automatically senses Positive & Negative voltage references
- Zero & Reset: Automatically Resets Timer and Display to 00.0 when Charge Plate Monitor voltage > ±1kV.
Reset indicated when Green LED
Decay Cycle Ready LED is ON
- Response: Approximately 200 milliseconds in combination with PFM-711A and Charge Plate Monitor
- Timing Range: From 0.2 to 159.9 seconds
- Timing Setpoints:
Reset when voltage input 100mv ±2 mv (1,000 Field Meter Volts ±20 V)
Cut Off Voltage @ 100 V: 10mv ±0.2 mv (100 Field Meter Volts ±2 V)
Cut Off Voltage @ 50 V: 5mv ±0.2 mv (50 Field Meter Volts ±2 V)
Cut Off Voltage @ 10 V: 1mv ±0.2 mv (10 Field Meter Volts ±2 V)
- Accuracy
Cut Off Voltage @ 100 V: Typically ±5%
Cut Off Voltage @ 50 V: Typically ±5%
Cut Off Voltage @ 10 V: Typically ±10%
- Power: One (1) standard 9 Volts battery, PROCELL, Eveready #216 (NEDA 1604, JIS 006P, IEC 6F22) Eveready #216
- Battery Life: > 40 hours typical
- Dimension (LxWxH): 4.50” x 2.75” x 1.0” (11.4 cm x 7 cm x 2.5 cm)
- Weight- 6.5 oz with battery installed (184g)