Detector: CsI(Tl), GM, 6LiF/ZnS
DER indication range: from 0.01 μSv/h to 200 mSv/h
DER measurement accuracy: ±(15 + 0.0015 / Ḣ) %; where Ḣ - measured dose equivalent rate value in mSv/h (in the range from 0.1 μSv/h to 100 mSv/h)
Energy range: 0.015 – 15 MeV (for gamma radiation)
Energy range:
within the range of energies from 0.015 to 0.045 MeV ± 40 %;
within the range of energies from 0.045 to 15.0 MeV ± 30 %
Neutron count rate: from thermal to 14MeV of β- radiation flux 0.15 – 3.5 MeV
Sensitivity, gamma radiation:
for 241Am in a Search mode: ≥ 200.0 s-1/(μSv/h)
for 137Cs in a Search mode: ≥ 200.0 s-1/(μSv/h)
for 137Cs in activity measurement mode ≥ 0,003 pulses·kg/s(cps·l/s)·Bq
Indication range:
gamma (in a search mode): 1 – 9999 cps
neutron (in a search mode): 0.01 – 999 cps
Sensitivity, neutron radiation:
for Pu-α-Be ≥ 0.1 pulses·cm2
for thermal neutrons ≥ 3.5 pulses·cm2
for Pu-α-Be (with neutron moderator) ≥ 0.6 pulses·cm2
Count rate indication range in the search mode: 1.00 – 2.7·105 s-1 - α-, β-, γ- radiation
Sensitivity to α-radiation (for Pu-239): ≥ 0.5 pulses·cm2
α-radiation flux density measurement range: 15.0 to 105 min-1·cm-2
α- radiation flux density accuracy:
in 200 μR/h gamma radiation field: ± 30 %
in 3.0·103 s-1 β-radiation field from the 90Sr+90Y source placed at 50 mm from the mica window of the detector: ± 15 %
α- radiation flux density accuracy:
on 239Pu in the range from 15.0 to 105 min-1·cm-2: ±(20 + 450/φ) %, where φ - measured α-radiation flux density, -1·cm-2
β- radiation flux density measurement range: 6.0 to 105 min-1·cm-2
β- radiation flux density accuracy:
on 90Sr+90Y: ± (20 + 60/φ) %, where φ - measured β-radiation flux density, min-1·cm-2
Sensitivity for β-radiation:
for 90Sr+90Y: ≥ 3.5 pulses·cm2
Activity measurement sample density range: 0.2 – 1.6 g/cm3
The number of γ-radiation scintillation spectra saved in the instrument’s memory: up to 1000
PC communication: USB interface
Power supply: 3.0 (+ 0.2; -0.4) V; two AA batteries or USB
Battery lifetime:
(in normal radiation background and provided LCD backlight, sound and light alarms are used no more than 5 minutes/day), at least: 210 h.
Ingress protection: IP65
Drop test on concrete floor: 0.7 m.
Operating temperature: -30 to up to +50 °С
Humidity: up to 95 % at 35 °С
Atmospheric pressure: from 84 to 106.7 kPa
Dimensions: 262х60х65 mm
Weight: ≤ 0.82 kg
Mean service lifetime: ≥ 10 years