VERT. SENSITIVITY FROM 1mV/DIV TO 15V/DIV.
SWEEP RATE FROM 10NS/DIV TO 1S/DIV.
COMPONENT TESTER.
DELAY SWEEP
CE, TUV GS, UL, CUL, IEC1010.

PS-605

CATHODE RAY TUBE 6 inch diagonal. rectangular screen with internal graticule 8 x 10 DIV
( 1 DIV = 1 cm ). P31 phosphor. 12 kV accel voltage.
VERTICAL DEFLECTION: Bandwidth DC-1 MHz ( -3db ).
Sensitivity: : 1 mV / DIV -1 V / DIV ( 20 MHz -3db ).
x 5 gain selected.5 mV / DIV -5 V / DIV
Attenuator: 1-2-5 sequence. 10 step with variable control.
Input Impedance: 1MΩ / - 2%, 25 pF / - 10 pF
Max. Input Voltage: 400 V ( DC AC peak ).
Rise Time: 5mV / DIV - 5 V / DIV : 5.8 nS
1mV / DIV : 17.5 nS
Over Shoot: Less than / - 5 %
Operation Mode: CH 1, CH 2, DUAL ( ALT, CHOP ).
Inverter: CH 2 only
HOLZONTAL DEFLECTION
X-Y Mode: switch selectable using X-Y switch
Accuracy: + / - 3%.
CH 1 : X axis.
CH 2 : Y axis.

Accuracy: Y - Axis / - 3 % X - Axis / - 6 %

Bandwidth: DC - 1 MHz ( -3db ).
X-Y Phase Difference: Approximately 3° at 50 kHz.
SWEEP SYSTEM
Sweep Display Mode: Main, Mix, Delay.
Hold Off Time: 5:1 continuously variable. ( 0.1μ ?S / DIV )
MAIN SWEEP
Sweep Speed: 0.1 μ S/div to 2S/div in 1-2-5 sequence, 23 steps.
Accuracy: -3 %.
Variable Time Control: 5:1, uncalibrated, continuously variable
between steps.
Sweep Magnification: 10X, 10% extend sweep speed up to
10 nS / DIV,
DELAY SWEEP
Sweep Speed: 0.1μ S/ DIV - 2S / DIV in 1-2-5 sequence 23 steps.
Accuracy: - 3%.
Sweep Magnification: 10X, 10% extend sweep speed
up to 10nS/DIV.
Delay Time Position: Variable control to located desirable 
waveform for extending.
TRIGGERING
Trigger Coupling: AUTO NORM. TV-V, TV-H.
Trigger Source: CH 1, CH2, ALT, LINE, EXT
Slope: -
TRIGGER SENSITIVITY COUPLING?? BANDWIDTH???? ? INT?? ? ?EXT
TV - V?????? DC - 1 kHz????? ?1.0 DIV? ??0.1
TV - H???? ?1kHz - 100kHz?????1.0 DIV? ? 0.1
AUTO????? 100Hz - 60MHz???1.5 DIV????0.1
NORM??? ? 100Hz - 60MHz???1.5 DIV????0.1
COMPONENT TEST
Test Voltage: Max. 6 Vrms ( open circuit ).
Test Current: Max. 11 mA ( shorted ).
Test Frequency: Line Frequency
Components: Capacitor, Inductor, Diode, Transistor, Zener etc.
CH 2 OUTPUT  
Output level: 100 mV / DIV ( no load ).
 50 mV / DIV ( with 50
£[ load ).
Bandwidth: 20 Hz-20 MHz ( -3db ).
Gratticule IIIumination: Adjustable.
Calibrator: Square wave 1 KHz ± 10 %, 2 Vp-p ± 3 %
Z-Modulation: Positive TTL signal, low level blank intensity 
at any intensity, high level unblank any intensity.
Trace Rotation: Adjustable on front panel.
Power Source: 115/230V AC ± 10%, 50/60 Hz.
Power Consumption: Apporx. 40 Watts.
Dimensions: 824 (W) x 398 (D) x 132 (H) mm.
Net Weig.g.ght: Approx. 7.8 kg.
Rated Range of Use: 10℃ - 35℃, 10-80% R.H.
Limits of Operation:  0℃ - 50℃, 10-80% R.H.
Storage Environment: - 30℃ - 70℃, 10-90% R.H.

 