Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Width: 3.5 in
Height: 0.95 in
Length: 3 in
Weight: 4.9 oz
Display: LCD
Software: Windows XP SP3/Vista/7 and 8 (32 and 64-bit)
Baud Rate: 250000
Materials: Plastic
Alarm Note: User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
Input Type: Internal
Calibration: Digital Calibration through Software
Data Format: atm, °C, dew point, °F, inHg, K, kPa, m, mbar, mg/mL, mmHg, MPa, Pa, PSI, °R, %RH, Torr
Form factor: Wall Mount
Samples,Max: 10752 Samples, Interval Selectable 1 Sec to 24 hrs
Start Modes: At set date and time, Button Push, Immediate Start, Next Interval
Battery life: 5 yr, typical with reading interval of 1 min
Memory Modes: Yes
RF Frequency: 2.45 GHz
Configuration: Omega Data Logging Software, Windows PC
Pressure, Max: 1300 mBar
Pressure, Min: 250 mBar
RH Resolution: 0.1%, 12 bit
Time Accuracy: ± 1 minute/month
Band Frequency: 2.405 to 2.475 GHz
Data Interface: Wireless, USB
Calibration Date: Automated
Measurement Type: Pressure, Relative Humidity, Temperature
LED Functionality: Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition
RF Frequency Note: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Relative Humidity: 0 to 95% RH non-condensing
Supply Power Type: Battery
Current Resolution: Temperature: 0.01°C, Resistance: 0.001 Ω
Band Frequency Note: ISM band 2.405 to 2.48 GHz (channels 11 through 25) @ 250 kbps data rate
Data Interface Note: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000- EXT required for wireless operation
Calibration Accuracy: Temperature: ± 0.5°C for 0 to 50°C, Pressure: ± 10 mbar, Relative Humidity: ± 3% RH
RH Measurement Range: 0 to 95% RH
Additional Features 1: Field Upgradeable
Battery Size and Type: Li-ion, 9V
Resistance Resolution: 0.001 Ω
Number of Measurements: 3
Temperature Resolution: 0.01 °C
Operating Temperature Note: -20 to 60°C, 0.002 to 100 psi
Operating Temperature, Max: 60 °C
Operating Temperature, Min: -20 °C
Temperature Measurement, Max: 60 °C