OMEGA FV-505C-F-D Vortex Flow Meters for Industrial Applications (4.13 GPM, 1/2 in, ANSI Flange, IP67 Type 4X (IEC 60529))

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Weight: 6 lb

Accuracy: ± 0.75 %

Display Type: LCD

Supply Power: 10.5 to 42 Vdc

Accuracy Note: ±0.75% of Reading (Liquid) (±0.5% of Reading: Typical Accuracy/ Non-Guaranteed) ±1% of Reading (Gas, Steam)

Detector Type: Integral

Output Detail: Pulse output,alarm output and status output use the common terminal, therefore these functions are not used simultaneously. Output Signal (◇): Dual Output (Both Analog and Transistor contact output can be obtained simultaneously). In this case refer to the item “Remarks on installation” for power supply and pulse output wiring. Analog: 4 to 20 mA DC, 2-wire system. Transistor Contact Output*: Open collector, 3-wire system. Pulse,alarm,status output are selected by parameter setting. Contact rating: 10.5 to 30 V DC, 120 mA DC*1 Low level: 0 to 2 V DC. *1: 10.5 to 30 V DC. 80 mA DC for ATEX Intrinsically Safe Approval (/KS2) and IECEx Intrinsically Safe Approval (/SS2)

Pressure Type: Gauge

Repeatability: ±0.2%

Data Interface: BRAIN Communication

Mounting Plates: Flange

Electrical Output: 4 to 20 mA, Two 125 mA SPST SSR

Enclosure Ratings: IP67 Type 4X (IEC 60529)

Materials, Wetted: JIS SUS348

Enclosure Material: N/A

Data Interface Note: Communication Signal: BRAIN or HART communication signal (superimposed on a 4 to 20 mA DC signal) Note: HART is a registered trademark of the HART Communication Foundation. Conditions of Communication Line: Load Resistance:250 to 600 Ω(including cable resistance). Supply Voltage:16.4 to 42 V DC for digital communications BRAIN and HART protocols. (16.4 to 30 V DC for intrinsically safe type). BRAIN: Space from other Power Line: 15cm or more (Parallel wiring should be avoided.) Communication Distance: Up to 2 km,when polyethylene insulated PVC- sheathed cables (CEV cables) are used. Communication distance varies depending on type of cable used and wiring. Load Capacitance: 0.22 µF or less Load Inductance: 3.3 mH or less Input Impedance Communicating Device: 10 kΩ or more at 2.4 kHz.

Media Compatibility: Gases, Liquids, Steam

Electrical Connection: 1/2 NPS female Conduit with Screw Terminal block

Operating Pressure, Max: 412 psi

Process Connection Size: 1/2 in

Process Connection Type: ANSI Flange

Volumetric Flow Rate, Max: 26 GPM

Volumetric Flow Rate, Min: 4.13 GPM

Electrical Connection Note: In case of /FF1 or /CF1, CF11, /KF2, /KS2, /SF2, /SS2 the screw length is deeper than ANSI standard for 0.5 to 2 threads.

Operating Temperature, Max: 250 °C

Operating Temperature, Min: -29 °C