For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.TH
0
Product image

NGI N62405-40-1000 Low Voltage High Current DC Electronic Load (5kW, 40V, 1000A)

ModelN62405-40-1000
OriginChina
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Voltage: 40V

Current: 1000A

Power: 5000W

Min operating voltage: 0.1V@500A/ 0.2V@1000A

CC mode

Range: 0~100A/ 0~1000A

Setting Resolution: 10mA/ 100mA

Setting Accuracy (23±5℃): Low range: 0.1%+0.1%F.S., High range: 0.1%+0.15%F.S.

CV mode

Range: 0~4V/ 0~40V

Setting Resolution: 0.1mV/ 1mV

Setting Accuracy: (23±5℃) 0.05%+0.05%F.S.

CP mode

Range: 0~5000W

Setting Resolution: 0.1W

Setting Accuracy (23±5℃): 0.5%+1%F.S

CR mode

Range: 0.001Ω~4Ω / 0.02Ω~40Ω

Setting Resolution: 16 bits

Setting Accuracy (23±5℃): 0.35%+0.781S / 0.35%+78.1mS

Slew Rate

Current: 16.7~1000A/ms / 1000~5000A/ms

Voltage: 0.334~16.7V/ms / 16.7~166.7V/ms

Power: 16.7~1000A/ms / 1000~5000A/ms

Resistance: 16.7~1000A/ms / 1000~5000A/ms

Voltage Measurement

Range: 0~4V/ 0~40V

Readback Accuracy (23±5℃): 0.05%+0.05%F.S.

Current Measurement

Range: 0~100A / 0~1000A

Readback Accuracy (23±5℃):0.1%+0.1%F.S.

Power Measurement

Range: 0~5000W

Readback Accuracy (23±5℃): 0.5%+1%F.S.

Dynamic Mode

T1& T2: 1~60000ms

Resolution: 1ms

Accuracy: 1ms+100ppm

Interface: LAN/RS232/CAN

AC Input: Single phase, 220V AC±10%, frequency 47Hz~63Hz

Sampling Frequency: 25Hz

Communication Response Time: ≤10ms

Operating Environment: Altitude: <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa

Temperature: Operating temperature: 0℃~40℃, storage temperature: -20℃~60℃

Net weight: Approx. 37kg

Dimension: 6U, 265.0(H)*482.0(W)with handle*612.0(D)mm

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts