Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Manuafacturer: Metrix
Model : MX 57EX
Item: MX0057CX
Warranty : 12 month
Technical specifications
- DC Tension: 5 calibres from 500 mV to 600 V
+ Accuracy: 0.025 %R + 2 D
- AC voltage : 5 calibres from 500 mV to 600 V
+ Accuracy: 0.3 %R + 30 D
+ Bandwidth: DC at 50 kHz
- DC Current: 500 μA, 5 mA; 50 mA & 500 mA
+ Accuracy: 0.2 %R + 2 D
- AC Current: 500 μA, 5 mA, 50 mA & 500 mA
+ Accuracy: 0.6 %R + 30 D
+ Bandwidth: DC at 5 kHz
- Resistance & Continuity: 6 ranges from 500 Ω to 50 MΩ
+ Accuracy: 0.07 %R + 2 D
+ Continuity: Detection threshold: from 10 Ω to 20 Ω. Response time 1 ms. Buzzer
- Test Diode: 0 to 2 V
- Capacitance:
+ Range: From 0.62 Hz to 500 kHz
+ Accuracy: 0.03 %R + 2 D
- Temperature: Range from -200 °C to +800 °C / Pt100 or Pt1000 platinum resistance probes
- Other measurements: Duty cycle, dB function and U2/R resistive power,Pulse width, timer,event counter
General specifications
- Display: 50,000 cts - 2 meas/s. Height of digits 14 mm – 2 meas/s
- Bargraph: 34-segment rapid analogue bargraph 20 meas/s
- Safety & Certification: ATEX 2014/34/UE Directive; EN/IEC 60079-0 – EN/IEC 60079-11; EN/IEC 61241-11 – EN/IEC 61241-0; EN/IEC 61010-1 – 600 V CAT III; CE inspection certificate number type LCIE 02 ATEX 6005 X and additional clauses LCIE 02 ATEX 6005X / 01, 02, 03, 04
- EMC: EN 61326-1
- Calibration: By PC software (option) with casing closed
- Power supply: One 9 V alkaline battery certified Ex (6LR61, MN1604) with low battery harge indicator
- Battery life: 300 hours. Automatic shutdown
- Ingress protection: IP67
- Dimensions : 189 x 82 x 40 mm / 400 g
State of delivery: delivered in a carrying case with 1 set of safety test-probe leads, 1 x 9 V battery, 1 spare intrinsic-safety fuse (0.5 A - 125 V) certified Ex and 1 operating manual.
Accessories:
- Rigid carrying case P01298004
- Accessories kit for electricity: 1 set of crocodile clips,1 set of crocodile-type wire grips,1 set of safety test probes,1 set of safety test-probe leads P01295459Z
- Optical communication kit/ RS232 for ASYC II SX--ASYC2HD
- Acquisition software for ASYC II SX-DMM2
- Metrology software on CD-ROM for MX58HD and MX59HD SX-ASYC2C/B
- Metrology software for MX57Ex MX57Ex-CAL
This ATEX-certified 50,000-count TRMS digital multimeter is designed for use in hazardous or explosive "gas" or "dust" environments, in compliance with the following standards:
Mine: Category Ex I M2
Surface industry: Category 2 (gas and dust) EX II 2 gd
Zone 1&2(gas) Ex ib I and Ex ib II T5 or T4 or T3
Zones 21&22(dust) EX ib D21 IP6X T°…°C
The temperature class depends on the battery used.
|
Certified battery |
Explosive gaseous atmosphere |
Combustible dusty atmosphere |
|
DURACELL PROCELL |
T5 |
T91 (°C) |
|
POWER LINE |
T4 |
T103 (°C) |
|
ANSMANN |
T4 |
T112 (°C) |
|
SANYO |
T4 |
T123 (°C) |
|
ENERGIZER |
T4 |
T124 (°C) |
|
POWER ONE |
T3 |
T133 (°C) |
It meets the following specifications:
- ATEX 2014/34/UE directive
- EN/IEC 60079-0 – EN/IEC 60079-11
- EN/IEC 61241-11 - EN/IEC 61241-0
- EN/IEC 61010-1 – 600 V CAT III+EN61010-2-030 2010
It is certified LCIE 02 ATEX 6005 X and EEx ib IIC T5/ EEx ib I ("old regulations") as per:
- CE inspection certificate number LCIE 02 ATEX 6005 X and additional clauses LCIE 02 ATEX 6005X / 01, 02, 03
It is equipped with a 500 mA fuse. It is delivered in a bag with some of its accessories.
• Bargraph; zoom or central zero
• VDC from 0.5 to 600 V ,
• AC and AC+DC voltage from 0.5 to 600 V, accuracy 0.025%
• Bandwidth: DC to 50 kHz
• AC and AC+DC current from 500 µA to 500 mA
• Resistance from 500 Ω to 50 MΩ
• MIN, MAX, Average and Peak
• Frequency, capacitance, temperature, dB, resistive power, duty cycle, pulse width/timer, event counter
• Continuity and iode tests