Function Description: AC/ DC/ IR

Withstand Voltage Test:

Lose Out Electricity Pressure

AC:

Voltage Range: 0.050kV - 5.000kV

Voltage Waveform: Sine wave

Distortion: <3%

Working Frequency: 50Hz, 60Hz optional

Frequency Accuracy: ±1%

Output Power: 100VA (20mA)

Voltage Regulation Rate: ±(1.0% +50V) (rated power)

DC:

Voltage Range: 0.050kV - 6.00kV

Signal Source Frequency: 600Hz

Output Power: 50VA (10mA)

Voltage Regulation Rate: ±(1.0% +100V) (rated power)

Voltage Resolution: 1V

Voltage Test Accuracy: ±2%

Voltage Generation Method: DDS signal source plus class AB power amplifier

Electricity Flow Measurement Test Fan Surround

AC:

Current Range: 0.001mA - 20.00mA

Short Circuit Current (Momentary): >40mA

Current Resolution: 0.001mA

Current Accuracy: ±(2% of reading + 2 words)

Actual Current: OFF - 0.001mA - 20mA

DC:

Current Range: 0.1μA - 10.00mA

Current Accuracy: ±(2% of reading + 2 digits)

Discharge Function: Automatic discharge after the test (DCW)

Insulation Resistance Test:

Output Voltage: 0.050V - 1.000kV

Voltage Resolution: 1V

Voltage Test Accuracy: ±2%

Maximum Output Current: 10mA

Maximum Output Power: 10VA (1000V/10mA)

Output Instantaneous Short-Circuit Current: >20mA

Load Regulation: ≤1% (rated power)

Ripple (1kV): ≤3% (1kV, no load)

Discharge Function: Automatic discharge after the test

Resistance Measurement Range: 0.1ΜΩ - 10GΩ

Resistance Measurement Accuracy:

Voltage < 500V: 0.2ΜΩ - 1GΩ Accuracy: ±[10% reading + 5 words], 1GΩ - 10GΩ Accuracy: ±[20% reading + 5 words]

Voltage > 500V: 0.2ΜΩ - 1GΩ Accuracy: ±[3% reading + 5 words], 1GΩ - 10GΩ Accuracy: ±[7% reading + 5 words]

Arc Detection:

Measuring Range: AC, DC: 1mA - 20mA (9 gears, fine-tuning)

Comparators:

Discrimination Method:

Window comparator mode at I at the ON: When I at < I_x < I_on, PASS; when I_x ≤ I or I_x ≥ I_on, FAIL (article items I_at < I_on)

I Down OFF: When I_x < I_up, PASS; when I_x ≥ I_up, FAIL; insulation resistance judgment method is the same as above

Capping Current I on: AC: 0.001mA - 20mA, DC: 0.1uA-10mA

Current Upper Limit Setting I under: AC: 0.001mA - 20mA, DC: 0.1uA-10mA

Resistance Upper Limit Setting: OFF - 0.2ΜΩ - 106Ω

Resistance Lower Limit Setting: 0.2ΜΩ - 106Ω

Parameter Setting:

Voltage Rise Time: 0.1s - 999.9s

Voltage Drop Time: 0s - 999.9s (only after withstand voltage PASS)

Voltage Waiting Time: 0.3s - 999.9s (only DC withstand voltage, and meet the rise time + test time > waiting time)

Test Time Setting: 0.3s - 999.9s (when TIMER ON)

Time Accuracy: ±(0.2% setting value ± 0.1s)

Protocol: SCPI, Modbus

Storege: 105 test files can be programmed, with 25 test steps per file

Interfaces: HANDLER, SIGNAL, RS232C, RS485 (optional)