Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Function Description: AC
Withstand Voltage Test:
Lose Out Electricity Pressure
AC:
Voltage Range: 0.050kV - 5.000kV
Voltage Waveform: Sine wave
Distortion: <3%
Working Frequency: 50Hz, 60Hz optional
Frequency Accuracy: ±1%
Output Power: 100VA (20mA)
Voltage Regulation Rate: ±(1.0% +50V) (rated power)
Voltage Resolution: 1V
Voltage Test Accuracy: ±2%
Voltage Generation Method: DDS signal source plus class AB power amplifier
Electricity Flow Measurement Test Fan Surround
AC:
Current Range: 0.001mA - 20.00mA
Short Circuit Current (Momentary): >40mA
Current Resolution: 0.001mA
Current Accuracy: ±(2% of reading + 2 words)
Actual Current: OFF - 0.001mA - 20mA
Arc Detection:
Measuring Range: AC: 1mA - 20mA (9 gears, fine-tuning)
Comparators:
Discrimination Method:
Window comparator mode at I at the ON: When I at < I_x < I_on, PASS; when I_x ≤ I or I_x ≥ I_on, FAIL (article items I_at < I_on)
I Down OFF: When I_x < I_up, PASS; when I_x ≥ I_up, FAIL; insulation resistance judgment method is the same as above
Capping Current I on: AC: 0.001mA - 20mA
Current Upper Limit Setting I under: AC: 0.001mA - 20mA
Resistance Upper Limit Setting: OFF - 0.2ΜΩ - 106Ω
Resistance Lower Limit Setting: 0.2ΜΩ - 106Ω
Parameter Setting:
Voltage Rise Time: 0.1s - 999.9s
Voltage Drop Time: 0s - 999.9s (only after withstand voltage PASS)
Voltage Waiting Time: 0.3s - 999.9s (only DC withstand voltage, and meet the rise time + test time > waiting time)
Test Time Setting: 0.3s - 999.9s (when TIMER ON)
Time Accuracy: ±(0.2% setting value ± 0.1s)
Protocol: SCPI, Modbus
Storege: 105 test files can be programmed, with 25 test steps per file
Interfaces: HANDLER, SIGNAL, RS232C, RS485 (optional)
Size (WxHxD): 215x143x405 mm (without terminal)
Weight: 12kg