Measurement Condition: Reflection: d/8(Diffused lighting, 8 degrees receiving)Compatible with SCI/SCE Measurement ISO7724/1、DIN5033 Teil7、JIS Z8722 condition C、CIE No.15、ASTM E1164)Transmission d/0(Diffused lighting, Vertical direction receiving)
Size of integrating sphere Φ15.2cm,Alvan diffused reflection surface coating
Illumination Light source: CLEDs(entire wavelength balanced LED light source)
Sensor: dual optical path sensor array
Wavelength range: 400-700nm
Wavelength interval: 10nm
Half spectral width: 5nm
Reflectivity range: 0-200%
Resolution: 0.01%
Observer angle: 2°/10°
Measurement Light Source: A,C,D50.D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10.F11,F12,CWF,U30.DLF,NBF,TL83,TL84
Data being displayed: SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color error tendency, history data color simulation, manual input standard sample, generate measurement report
Measurement time interval 2 second
Color space: CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab , Munsell MI,CMYK, RGB, HSB
Color difference formulas: ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00.ΔEab(Hunter),555color classification
Other colorimetric indices: WI(ASTM E313-00.ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00.ASTM E313-73), Tint(ASTM E313,CIE,Ganz), metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner
Repeatability
light splitting reflectivity: standard deviation within 0.08%
color values: ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum: 0.03
Interface: USB
Data storage: mass storage
Light source longevity: 5 years, 1.5 million tests
Size: 583*330*304mm(L*W*H)
Work temperature range: 15℃-32℃ (60°F-90°F)
Relative Humidity: 0℃ to 45℃,relative humidity 80% or below(at 35°C ), no condensation
Standard accessories: AC power line, color management software, drive software, USB cable, black/white calibration tube, 40*10cuvette, cuvette support, testing report
Optional: 40x40 cuvette