IILumination/viewing system:
di: 8°, de: 8° (diffuse light: 8° viewing)
SCI (specular component included)/SCE (reflective component not included) switchable
Integrating sphere: Ø54 mm
Light source: Pulsed xenon lamp × 2
Detector: Dual 40-element silicon photodiode array
Spectrophotometer: Planar diffraction grating
Wavelength Range: 360 to 740 nm
Measuring wavelength: 10 nm
Half bandwidth: Approximately 10 nm
Reflectance Range: 0 to 175%;resolution: 0.01
Measuring area:
MAV: Ø8 mm
SAV: Ø3 mm
Repeatability:
Standard deviation within ΔE*ab 0.02
(When white calibration plate is measured 30 times within 5 seconds interval after white calibration)
Differences between measuring instruments:
In the range E*ab 0.12
(Based on averages for the 12 BCRA Series II color plots; MAV SCI; compared to values measured by main meter under KONICA MINOLTA standard measuring conditions)
UV adjustment: 100%/0%/Adjusted (Instant UV adjustment without mechanical filter movement); 400nm . UV cut filter
Observation: 2° viewing angle, 10° . viewing angle
Illumination: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65, user-defined illuminator (Can be evaluated simultaneously with two light sources)
Display: Colorimetric value/graph, color difference value/graph, spectrogram, pass/fail rating, false color
Colorimetric values: L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and color difference in these spaces; Munsell (C)
Standards: MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE/Ganz), intensity, opacity, gray scale (ISO 105-A05), gloss value 8°, user standard
Color difference equation: ΔE*ab (CIE1976)/ΔE94 (CIE1994)/ΔE00 (CIE2000)/CMC (l: c)/Hunter ΔE/DIN99o
Applicable standards: DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15
Measurement time: About 0.7 seconds. (Measuring mode: SCI or SCE) (From pressing the trigger button to completing the measurement)
Minimum measurement interval: Approx. 1.5 seconds (Measurement mode: SCI or SCE)
Data memory: 1,000 target data + 5,100 sample data
Battery performance:
Measurement mode: SCI or SCE
Approximately 3,000 measurements (approximately 1,000 when using Bluetooth) when taking measurements over a 10-second interval at 23°C using a dedicated lithium battery
Viewfinder function: Available (with white illumination LED)
Display: 2.7-inch color TFT-LCD monitor with reversible portrait view
Display language: English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese, Russian, Turkish, Polish
Connectivity: USB 2.0; Bluetooth (Compatible with SPP. Optional Bluetooth module required)
Power:
Dedicated lithium-ion battery (removable), USB port power (lithium-ion battery installed),
Dedicated AC adapter (lithium-ion battery installed)
Charging time: About 6 hours
Operating temperature/humidity range: Temperature: 5 to 40°C, Relative humidity: 80% or less (at 35°C) non-condensing
Storage temperature/humidity range: Temperature: 0 to 45°C, Relative humidity: 80% or less (at 35°C) non-condensing
Dimensions: Approx. 81 (W) × 93 (H) × 229 (D) mm
Weight: About 630 g