Direct access to our certified experts

Source
DC Ratings
• Voltage: 0 to 80 V
• Current: 0 to ± 40 A
• Power: 0 to ± 2 kW
Output Ripple and Noise
• CV peak-to-peak: ≤ 200 mVp-p
• CV rms: ≤ 80 mVrms
Load Effect (Load Regulation)
• Voltage: 16 mV
• Current: 40 mA
Load Transient Recovery Time
• Recovery time: ≤ 1 ms
• Settling band: 0.8 V
Load
DC Ratings
• Voltage: 0 to 80 V
• Current: 0 to 40 A
• Power: 0 to 2 kW
Load Effect (Load Regulation)
• Voltage: 16 mV
• Current: 40 mA
Programming Accuracy
• Voltage: 0.03% + 24 mV
• Current: 0.1% + 40 mA
• Power: 0.5% + 10 W
Measurement Accuracy
• Voltage: 0.03% + 24 mV
• Current: 0.1% + 60 mA
• Power: 0.5% + 10 W
*For detailed specifications, please refer to the Datasheet.