Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

DC Ratings:
Voltage 80 V
Current 80 A
Power 4 kW
Programming Accuracy
Voltage 0.03% + 24 mV
Current 0.1% + 80 mA
Resistance 3 mΩ
Power 0.5% + 20 W
Readback Accuracy
Voltage 0.03% + 24 mV
Current 0.1% + 120 mA
Power 0.5% + 20 W.
Load Regulation:
Voltage ≤ 16 mV
Current ≤ 80 mA.
Constant voltage mode programming and readback:
Range: 0 to 80 V
Resolution: 1 mV
Temperature coefficient: ≤ 30 ppm/°C
Constant current mode programming and readback:
Range: 0 to 80 A
Resolution: 10 mA
Temperature coefficient: ≤ 50 ppm/°C
Constant resistance mode Programming:
Load resistance range: 0.015 to 1,200 Ω
Resolution: 1 mΩ
Constant power mode programming and readback:
Range: 0 to 4 kW
Resolution: 1 W
Maximum slew rate
Rise/Fall slope: 20 A/ms
Line regulation:
Voltage: ≤ 16 mV
Current: ≤ 48 mA
Protection capability:
Overvoltage: 82 V
Overcurrent: 84 A
Overpower: 4,080 W
*For detailed specifications, please refer to the Datasheet.
*Images for illustration purposes only.