AC input
Connections: L1, L2, L3, PE (3-phase with protective earth; no neutral)
Voltage: 200 VAC -15% to 240 VAC +10%, line-to-line
Maximum Phase Current (A RMS): 13.1 A
Frequency: 50/60 Hz
DC Power Ratings
• Voltage: 0 to 20 V
• Current: 0 to 170 A
• Power: 3,400 W
Output Ripple and Noise
• CV rms: 10 mV
• CV peak-to-peak: 75 mV
Load Regulation
• Voltage: 7 mV
• Current: 136 mA
Line Regulation
• Voltage: 2 mV
• Current: 85 mA
Voltage Programming Accuracy
• Voltage: 10 mV
Current Programming Accuracy
• Current 0.1%+: 340 mA
Voltage Measurement Accuracy
• Voltage: 10 mV
Current Measurement Accuracy
• Current: 340 mA
Transient Response
• Recovery time: 1 ms
• Settling band: 0.1 V
*For detailed specifications, please refer to the Datasheet.