Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
SPECIFICATION
Pipe diameter range: 10 mm to 3,000 mm
Temperature range for sensors: -50 °C to +115 °C (-58 °F to +239 °F) , higher temperatures available on request
Robust IP 66 un it with LCD display and glass-fronted keypad
Epoxy-coated aluminium or stainless steel enclosure
Magnetic pen for safe and easy programming
Measurement of two flows simultaneously
PERFORMANCE
Measurement principle: Ultrasonic transit-time difference
Flow velocity range: 0.01 ... 25 m/s
Resolution: 0.25 mm/s
Repeatability: 0.15 % of measured value, ±0.015 m/s
Accuracy:
Volume flow:
±1 ... 3 % of measured value depending on application
±0.5 % of measured value with process calibration
Flow velocity (mean): ±0.5 % of measured value
Turn down ratio: 1/100 (equivalent to 0.25 ... 25 m/s)
Measurement rate: 100 Hz (standard)
Response time: 1 s (standard); 90 m/s (optional)
Damping of displayed value: 0 ... 99 s (selectable by user)
Gaseous and solid content of liquid media: < 10 % of volume