Measurement Methods:
Hydrostatic pressure measurement using Piezoresistive technology
Conductivity measurement according to EPA Method 120.1; Standard Method 2510
Temperature measurement according to EPA Method 170.1
Measurement Ranges & Accuracy:
Conductivity: 0 - 100,000 µS/cm; ±0.5% of the reading
Salinity: 0 - 42 PSU
Total Dissolved Solids (TDS): 0 - 82 ppt
Resistivity: 10 - 200,000 Ohms-cm; 0.98 to 1.14 g/cm³
Level Measurement:
Non-vented cable type: 0 - 11/60/200 meters
Vented cable type: 0 - 3.5/11/21/70/210 meters
Accuracy: ±0.05% of the full scale
Resolution: ±0.005% of the full scale or better
Materials:
Sensor body & diaphragm: Titanium, Delrin
Conductivity sensor core: PVC
Measurement Units:
Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH₂O, inH₂O
Level: in., ft, mm, cm, m
Temperature Sensor:
Type: Silicon
Accuracy: ±0.1°C
Resolution: 0.01°C or better
Units: °C or °F
Additional Specifications:
Data logging rate: 2 seconds
Battery: 3.6V Lithium, lifespan up to 5 years
Power supply: 8 to 36 VDC
Output signals: Modbus/RS485; 4-20mA; SDI-12
Memory capacity: Stores up to 190,000 records and 50 logs
Operating temperature: 2 to 50°C