Measuring range |
F400 :0~400μm N400:0~400μm F1:0~1250μm F1/90:0~1250μm N1:0~1250μm F10:0~10000μm CN02:10~200μm |
|||||||||||||
|
Measuring accuracy |
F400, N400 1 point calibration:±(2%+0.7)2 point calibration:±(1%+7)F1, F1/90, N1, CN02 1 point calibration:±(2%+1)2 point calibration:±(1%+1)F10 1 point calibration:±(2%+10) 2 point calibration:±(1%+10) |
|||||||||||||
|
Calibration |
1 point calibration /2 point calibration /basic calibration |
|||||||||||||
|
Display resolution |
0.1um (0~99.9um) / 1um (Over 100um) |
|||||||||||||
|
Weight |
250g(including battery package ) |
|||||||||||||
|
Operation environment |
Temperature: 0℃~50℃ humidity: 20%RH~90%RH |
|||||||||||||
|
Operation mode |
Direct testing mode and block statistics mode |
|||||||||||||
|
Measuring mode |
continuous/single |
|||||||||||||
|
Shutdown mode |
manual/automatic |
|||||||||||||
|
Operation alarm |
Ring music to alarm mistake |
|||||||||||||
|
Signal Dealing |
||||||||||||||
|
Threshold |
Limits setting and automatically alarm measured values out of limit |
|||||||||||||
|
Data analysis |
Analyzing a batch of measuring values via histogram |
|||||||||||||
|
Statistic function |
Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum |
|||||||||||||
|
Data Merory |
||||||||||||||
|
Thickness values |
500 measuring data |
|||||||||||||
|
Delete |
Single doubtful data / All data of one group |
|||||||||||||
|
Input/Output |
||||||||||||||
|
|
measured values, statistic values, limit values and histogram |
|||||||||||||
|
Communication |
RS232/USB |
|||||||||||||
|
Power supply |
||||||||||||||
|
Battery |
9V Nickel-hydride/alkaline batteries |
|||||||||||||
|
Power battery inspection |
low voltage indication |
|||||||||||||
|
Standard delivery |
Main unit |
1 |
||||||||||||
|
Integrated probe ((N1orF1) |
1 |
|||||||||||||
|
Calibration foil set |
4 |
|||||||||||||
|
Calibration base set |
1 |
|||||||||||||
|
9V alkaline battery |
1 |
|||||||||||||
|
Instruction manual |
1 |
|||||||||||||
|
Printer RD-E32-SN |
1 |
|||||||||||||
|
Software CTG Insight |
1 |
|||||||||||||
|
Optional accessories |
||||||||||||||
|
probe |
F400 F1 F1/90° F10 N400 N1 CN02 |
|||||||||||||
|
Probe model
|
F400 |
F1 |
F1/90° |
F10 |
N400 |
N1 |
CN02 |
|
||||||
|
Working principle
|
magnetic induction |
induced eddy current |
|
|||||||||||
|
Measuring range(mm) |
0~400 |
0~1250 |
0~10000 |
0~400 |
|
10~200 |
|
|||||||
|
( chromeplating upon copper base set 0~40) |
|
|||||||||||||
|
Resolution (mm) |
0.1 |
0.1 |
10 |
0.1 |
0.1 |
1 |
|
|||||||
|
Tolerance |
1point calibration (mm) |
±(3%H+0.7) |
±(3%H+1) |
±(3%H+10) |
±(3%H+0.7) |
±(3%H+1.5) |
±(3%H+1) |
|
||||||
|
2point calibration (mm) |
±(1%H+0.7) |
±((1%H+1) |
±(1%H+10) |
±(1%H+0.7) |
±(1%H+1.5) |
-------- |
|
|||||||
|
Measuring condition
|
Min curvature radius (mm)
|
convex |
1 |
1.5 |
flat |
10 |
convex |
1.5 |
3 |
flat |
Only flat |
|
||
|
Min measure area(mm)
|
F3 |
F7 |
F7 |
F4 |
F4 |
F5 |
F5 |
F7 |
|
|||||
|
Critical substrate thickness(mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
0.3 |
0.3 |
No limit |
||||||