Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Measurement functions: pH, Dissolved Oxygen, Conductivity, Salinity, TDS, Seawater specific gravity, Temperature, ORP (Oxidation Reduction Potential), Turbidity, and depth
Sensor probe
Max.items displaying simultaneously: 11
Measurement temperature: -10 to 55 C
Max. sensor diameter: Approx. 96mm
Probe length: Approx. 340mm
Mass: Approx. 1800g (3.97 lbs)
Automatic calibration: Yes
Measurement depth: Max. 30 m
Material contact with liquid: PPS, glass, SUS316L, SUS304, FKM, PEEK, Q,Titanium, FEP membrane, POM
Water resistance: JIS protection level 8
Turbidity wiper
Monitor
LCD: 320 X 240 liquid crystal display with backlight (black and white)
Data memory: 10,000
Water resistance: JIS protection level 7 (when sensor cable is fitted)
Communication: USB
Battery life: Approx. 500 measurements
Outer dimensions: 115(W) X 66(D) X 283(H) mm
pH
Measurement principle: Glass electrode method
Range: pH 0 to 14
Resolution: 0.01pH
Repeatability: +/- 0.05pH
Accuracy: +/- 0.1pH
Two-point calibration
Automatic temperature compensation
Oxidation Reduction Potential (ORP)
Measurement principle: Platinum electrode method
Range: -2000 mV to +2000 mV
Resolution: 1 mV
Repeatability: +/- 5 mV
Accuracy: +/- 15 mV
Dissolved Oxygen
Salinity conversion (0 to 70 PPT / automatic)
Automatic temperature compensation
Measurement principle: Polarographic method
Range: 0 to 50.0 mg/L
Resolution: 0.01 mg/L
Repeatability: +/- 0.1 mg/L
Accuracy: 0 to 20 mg/L: +/- 0.2 mg/L; 20 to 50 mg/+/- 0.5 mg/L
Conductivity
Measurement principle: 4 AC electrode method
Range: 0 to 10 S/m (0 to 100 mS/cm)
Resolution: 0.000 to 0.999 mS/cm:0.001, 1.00 to 9.99 mS/cm: 0.01, 10.0 to 99.9 mS/cm: 0.1, 0.0 to 99.9 mS/m: 0.1, 0.100 to 0.999 S/m: 0.001, .00 to 9.99 S/m: 0.01
Repeatability: +/- 0.05% F.S.
Accuracy: *+/- 1% F.S.(Median of two-point calibration)
Auto range
Automatic temperature conversion (25 C)
Salinity
Measurement principle: Conductivity conversion
Range: 0 to 70 PPT (permillage)
Resolution: 0.1 PPt
Repeatability: +/- 1 PPT
Accuracy: +/- 3 PPT
Total Dissolved Solid (TDS)
Measurement principle: Conductivity conversion
Range: 0 to 100 g/L
Resolution: 0.1% F.S.
Repeatability: +/- 2 g/L
Accuracy: +/- 5 g/L
Seawater specific gravity
Measurement principle: Conductivity conversion
Range: 0 to 50 delta T
Resolution: 0.1 delta T
Repeatability: +/- 2 delta T
Accuracy: +/- 5 delta T
Temperature
Measurement principle: Thermistor method
Range: -10 to 55 C
Resolution: 0.01 C
Repeatability: *+/- 0.10 C (at calibration point)
Accuracy: JIS class B platinum thermometer sensor (+/- 0.3+0.005 |t|)
Turbidity (TURB)
Measurement principle: Tungsten lamp source and 90 degrees scattering method
Range: 0 to 800 NTU
Resolution: 0 to 9.99 NTU: 0.01,10 to 99.9 NTU: 0.1, 100 to 1000 NTU: 1,
Repeatability: +/- 3% (reading) or +/- 0.1 NTU whichever is greater
Accuracy: 0 to 10 NTU: +/- 0.5 10 to 1000 NTU: 3% (reading) or +/- 1 NTU whichever is greater
Water depth
Measurement principle: Pressure method
Range: 0 to 30 m
Resolution: 0.05 m
Repeatability: +/- 1% F.S.
Accuracy: +/- 0.3 m