-Functions:
Navigation function
User guide
Printer connectivity (GLP / GMP)
Temperature compensation (auto / manual)
Auto-hold function
Security (password)
Version up function
Characteristics: Channel 1: pH + ORP
-pH:
Method of measurement: Glass electrode
Measuring range: pH 0.000 ~ 14,000
Display range: pH -2,000 ~ 20.000
Resolution: 0.01/0.001 pH
Repeatability: ±0.001 pH±1 digit
pH calibration points: 5
Repeatability check
Alarm limit of calibration
-mV (ORP):
Measuring range: ± 1999.9 mV
Resolution: 0.1 mV
Repeatability: ± 0.1 mV ± 1 digit
-Temperature:
Measuring range: 0.0 ~ 100.0oC (-30.0 ~ 130.0oC)
Resolution: 0.1oC
Repeatability: ± 0.1 ° C ± 1 digit
-ION:
Method of measurement: ion electrode method
Measuring range: 0.00 µg / L ~ 999 g / L (mol / L)
Resolution: Valid number 3 digits
Repeatability: ± 0.5% F.S. ± 1 digit
Calibration curve point: 5
-Conductivity:
Measurement method: 2 AC bipole electrodes
Measuring range (display range): 0.0 μS / cm ~ 19.99 μS / cm: cell constant 0.1 / cm
0.000 mS / cm ~ 199.9 mS / cm: 1.0 / cm cell constant
0.00 mS / cm ~ 1999.0 mS / cm: cell of 10.0 / cm
Resolution: 0.05% F.S
Repeatability: ± 0.5% F.S. ± 1 digit
Change unit
Distilled water temperature conversion
Periodical check
-Salinity:
Method of measurement: Conversion from conductivity value
Measuring range (display range): 0.00 ~ 80.00 ppt (0.000% ~ 8000%)
Resolution: 0.01 ppt (0.001%)
Salt concentration calibration
-Resistor:
Method of measurement: Convert from conductivity value
Measuring range (display range): 0.0 Ω * cm ~ 199.9 MΩ * cm: cell constant - 0.1 / cm
0.00 Ω * cm ~ 19.99 MΩ * cm: cell constant - 1.0 / cm
Resolution: 0.05% F.S.
Repeatability: ± 0.5% F.S. ± 1 digit
-TDS:
Measurement method: Conversion from conductivity value (EN27888 or TDS coefficient)
Measuring range (display range): 0.01 mg / L ~ 1000 g / L
Resolution: 0.01 mg / L
-Input / Output:
Input (number of channel): 2
USB peripharals (communication with PC)
RS-232C (Printer / Personal Computer)
-Data:
Memory number: 2000
Interval memory
ID input
-Display:
Display : LCD
Dual component display
Ambient temperature: 0 ~ 45oC
Power: AC Adapter 100 ~ 240V 50/60 Hz
Dimensions: 170 × 174 × 73 mm (Excluding electrodes and AC adapters)
Power consumption: Approx. 0.7 VA
Mass of main unit: Approx. 500 g