Accuracy: ±2% or 0.01 NTU from 0 - 40 NTU; ±10% of reading from 40 - 1000 NTU based on Formazin primary standard
Cable Length: 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration Method: For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range; Custom calibration for up to 6-point calibrations
Certifications: CE compliant; US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version; Australian ACMA Marking
Communication: None
Controller: Sensor Only
Dimensions (H x W x D): 249 mm x 268 mm x 190 mm
Enclosure Rating: Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument
Fitting Type: Sample quick connector: ¼-in. for ¼-in. tubing
Instrument: Standard Process Head
Light Source: Class 2 laser product, with embedded 650 nm (EPA) or 850 nm (ISO), max. 1.0 mW Class 2 laser source (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Lower Limit of Detection (LOD): 0.002 NTU
Material: ASA S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS
Model: TU5300sc
Mounting Configurations: Wall Mount
Operating Humidity: Relative humidity: 5 - 95% at different temperatures, non-condensing
Operating Temperature Range: 0 - 50 °C (32 - 122 °F)
Options: Process Head Only
Power Requirements (Voltage): None
Range: EPA: 0 - 700 NTU / FNU / TE/F / FTU; 0 - 175 EBC
Regulatory: EPA
Repeatability: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
Resolution: 0.0001 NTU / FNU / TE/F / FTU / EBC
Response Time: T90 <45 seconds at 100 mL/min
Sample Flow Rate: 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min
Sample Pressure: 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F)
Sample Temperature: 2 - 60 °C (35 - 140 °F)
Signal Average Time: 30 - 90 seconds
Storage Conditions: -40 - 60 °C (-40 - 140 °F)
Stray Light: <10 mNTU
System Check: No
Units: NTU, FNU, TE/F, FTU, EBC
Verification: Liquid: Stablcal®, Formazin (0.1 to 40 NTU); Dry: Glass Rod at<0.1 NTU
Weight: 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories
What's included?: TU5300sc Turbidimeter, User Manual, Wall Mount, Vial Replacement Tool, Screw Set, Drying Cartridge, Flow Regulator, Service Bracket