Accuracy

±0.02 mV or 0.05%, whichever is greater

Cable Length

1 m (3.28 ft)

Electrode Type

Non-Refillable Dritek Gel Reference Element

ISA Required

Fluoride ISA
(#258999)

Junction

Annular Junction (PTFE)

Kit?

Yes

Length

175 mm (6.89 in.)

Method Type

Laboratory: Non-Refillable Dritek Gel Reference Element

Parameter

Fluoride

Probe Type

Standard

Product Kit

Model: ISEF121
Accessories Included: Calibration Reagents Pack

Range

0.01 mg/L (5 x 10-7 M) - 19 g/L (1 M) F⁻

Reference Type

Ag/AgCl

Resolution

Selectable up to 4 significant digits

Sample depth

25.4 mm (1 in.)

Sample Volume

25 mL

Sensor material

Epoxy

Sensor Type

Solid-state crystal membrane

Special Features

Dry storage & fast response time. No replacement membranes.

Temperature Accuracy

±0.3 °C (±0.54 °F)

Temperature Range

5 - 50 °C (41 - 122 °F)

Temperature Resolution

0.1 °C (0.18 °F)

Test requirements

Parameter Needed: Fluoride
Minimum Sample Depth (mm): 26

Thermistor

ATC

Warranty

12 months

Weight

0.15 kg

Accuracy

±0.02 mV or 0.05%, whichever is greater

Cable Length

1 m (3.28 ft)

Electrode Type

Non-Refillable Dritek Gel Reference Element

ISA Required

Fluoride ISA
(#258999)

Junction

Annular Junction (PTFE)

Kit?

Yes

Length

175 mm (6.89 in.)

Method Type

Laboratory: Non-Refillable Dritek Gel Reference Element

Parameter

Fluoride

Probe Type

Standard

Product Kit

Model: ISEF121
Accessories Included: Calibration Reagents Pack

Range

0.01 mg/L (5 x 10-7 M) - 19 g/L (1 M) F⁻

Reference Type

Ag/AgCl

Resolution

Selectable up to 4 significant digits

Sample depth

25.4 mm (1 in.)

Sample Volume

25 mL

Sensor material

Epoxy

Sensor Type

Solid-state crystal membrane

Special Features

Dry storage & fast response time. No replacement membranes.

Temperature Accuracy

±0.3 °C (±0.54 °F)

Temperature Range

5 - 50 °C (41 - 122 °F)

Temperature Resolution

0.1 °C (0.18 °F)

Test requirements

Parameter Needed: Fluoride
Minimum Sample Depth (mm): 26

Thermistor

ATC

Warranty

12 months

Weight

0.15 kg