For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.TH
0
Product image

HACH ISECL181AP Đầu đo ISE Chloride kèm theo phụ kiện phân tích

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Accuracy

±0.02 mV or 0.05%,
whichever is greater

Cable Length

1 m (3.28 ft)

Electrode Type

Non-Refillable Dritek
Gel Reference Element

ISA Required

Chloride ISA
(#2318069)

Junction

Double Junction
(ceramic Porous Pin
and annular porous PTFE)

Kit?

Yes

Length

175 mm (6.89 in.)

Method Type

Laboratory: Non-Refillable
Dritek Gel Reference Element

Parameter

Chloride

Probe Type

Standard

Product Kit

Model: ISEF121
Accessories Included:

Calibration Reagents Pack

Range

0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻

Reference Type

Ag/AgCl

Resolution

Selectable up to 4 significant digits

Sample depth

25.4 mm (1 in.)

Sample Volume

25 mL

Sensor material

Epoxy

Sensor Type

Solid-state crystal membrane

Special Features

Dry storage & fast response time.
=No replacement membranes.

Temperature Accuracy

±0.3 °C (±0.54 °F)

Temperature Range

5 - 50 °C (41 - 122 °F)

Temperature Resolution

0.1 °C (0.18 °F)

Test requirements

Parameter Needed: Chloride
Minimum Sample Depth (mm): 26

Thermistor

ATC

Warranty

6 months

Weight

0.15 kg

Accuracy

±0.02 mV or 0.05%,
whichever is greater

Cable Length

1 m (3.28 ft)

Electrode Type

Non-Refillable Dritek
Gel Reference Element

ISA Required

Chloride ISA
(#2318069)

Junction

Double Junction
(ceramic Porous Pin
and annular porous PTFE)

Kit?

Yes

Length

175 mm (6.89 in.)

Method Type

Laboratory: Non-Refillable
Dritek Gel Reference Element

Parameter

Chloride

Probe Type

Standard

Product Kit

Model: ISEF121
Accessories Included:

Calibration Reagents Pack

Range

0.1 mg/L (3 x 10-6 M) - 35.5 g/L (1 M) Cl⁻

Reference Type

Ag/AgCl

Resolution

Selectable up to 4 significant digits

Sample depth

25.4 mm (1 in.)

Sample Volume

25 mL

Sensor material

Epoxy

Sensor Type

Solid-state crystal membrane

Special Features

Dry storage & fast response time.
=No replacement membranes.

Temperature Accuracy

±0.3 °C (±0.54 °F)

Temperature Range

5 - 50 °C (41 - 122 °F)

Temperature Resolution

0.1 °C (0.18 °F)

Test requirements

Parameter Needed: Chloride
Minimum Sample Depth (mm): 26

Thermistor

ATC

Warranty

6 months

Weight

0.15 kg

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts