AC WITHSTANDING
Output-Voltage Range: 0.050kV~5.000kV
Output-Voltage Resolution: 1V
Output-Voltage Accuracy: ± (1% of setting + 5V)
[no load]
Maximum Rated Load: 200 VA (5kV/40mA)
Maximum Rated Current: 40mA (0.5kV< V ≦ 5kV)
10mA (0.05kV≦ V ≦ 0.5kV)
Output-Voltage Waveform: Sine wave
Output-Voltage Frequency: 50 Hz / 60 Hz selectable
Voltage Regulation: ± (1% + 5V) [maximum
rated load → no load]
Voltmeter Accuracy: ± (1% of reading + 5V)
Current Measurement Range: 1μA~40.00mA
Current Best Resolution: 1μA / 10μA
Current Measurement Accuracy: ±(1.5% of reading +
30μA)
Window Comparator Method: Yes
ARC Detect: Yes
RAMP UP (Rise Time): 0.1s~999.9s
RAMP DOWN (Fall Time): 0.0s~999.9s
TIMER
(Test Time): OFF, 0.3s~999.9s
WAIT TIME: 0.0s~999.9s
GND: ON/OFF
DC WITHSTANDING
Output-Voltage Range: 0.050kV~6.000kV
Output-Voltage Resolution: 1V
Output-Voltage Accuracy: ± (1% of setting + 5V)
[no load]
Maximum Rated Load: 50W (5kV/10mA)
Maximum Rated Current: 10mA (0.5kV< V
≦ 6kV)
2mA (0.05kV≦ V ≦ 0.5kV)
Voltage Regulation: ± (1% + 5V) [maximum rated
load → no load]
Voltmeter Accuracy: ± (1% of reading + 5V)
Current Measurement Range: 1μA~10.00mA
Current Best Resolution: 0.1μA /1μA
/10μA
Current Measurement Accuracy: ±(1.5% of reading + 3μA)
when I Reading < 1mA
±(1.5% of reading + 30μA) when I Reading ≧ 1mA
Window Comparator Method: Yes
ARC Detect: Yes
RAMP UP (Rise Time): 0.1s~999.9s
RAMP DOWN (Fall Time): 0.0s~999.9s
TIMER (Test Time): OFF, 0.3s~999.9s
WAIT TIME: 0.0s~999.9s
GND: ON/OFF
Continuity Test
Output-Current : 100mA dc (fixed)
Ohmmeter Measurement Range: 0.10W~ 70.00W
Ohmmeter
Measurement Resolution: 0.01W
Ohmmeter
Measurement Accuracy: ±(10% of reading +
2W)
Window Comparator Method : Yes
TIMER (Test Time): 0.3s~999.9s
MEMORY
Single Step Memory MANU: 100 blocks
Automatic Testing Memory AUTO: 100 blocks, manu per auto: 10
INTERFACE
Front panel REMOTE terminal, USB host
Rear panel Rear Output, RS-232C , USB device, Signal I/O, GPIB (Optional)
DISPLAY: 7” color LCD
POWER SOURCE: AC 100V~240V ± 10%, 50Hz/60Hz; Consumption: 400VA
DIMENSION & WEIGHT: 380(W) x 148(H) x 454(D) mm; Approx. 15kg