- Maximum AC current: 3000A AC
- AC current ranges and resolution: 30.00A, 300.0A, 3000A
- Basic AC current accuracy(of reading): ± 3.0% + 5 digits
- Measurement rate: 1.5 samples per second, nominal
- AC current bandwidth: 45Hz – 500Hz (sine wave)
- Positional error(distance from optimum)
1.4” (35mm) 1.0%
2.0” (50mm) 1.5%
2.4” (60mm) 2.0%
- Minimum requirements for meter compatibility with TA72: AC voltage function 4000
count display 1mV resolution
- Max conductor diameter: 2.4" (6cm)
- Flex coil length: 10" (25 cm)
- Flex coil diameter: 0.3” (7.5mm)
- Flex coil tip diameter: 0.5” (13mm)
- Probe length: 73" (1.9m)
- Worklight: Two white LEDs
- Power supply: (2) 1.5V “AAA”
- Drop test: 9.8' (3m)
- Agency approvals: CE, UL
- Safety rating: CAT IV 600V, CAT III 1000V
- Standards: EN61010‐1, EN61010‐2‐032