Calibration: sulfur dioxide SO2
Sensor type: electrochemical
Sampling method: diffusion
Detection range: 0...50 ppm SO2
0...2000 ppm SO2
Resolution: 0.1 ppm SO2 for 50 ppm range
1 ppm SO2 for 2000 ppm range
Sensor lifetime: > 2 years
Power supply: 12...36 VDC (default), 24 VAC or 230 VAC as options
Digital interface: RS485, Modbus RTU protocol
Analog outputs: 2 × 4-20 mA / 0-10 V, user settable
Output relays (option): 2 × SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max
Enclosure: grey ABS plastic, wall mount, IP65
Dimensions: H90 × W145 × D55 mm
Operating conditions: -30...+50 °C, 15...90 %RH