- Conductivity

Range:

... to 1.999 µS/cm ; ... to 19.99 µS/cm ;

... to 199.9 µS/cm ; ... to 1999 µS/cm ;

... to 5000 µS/cm ; ... to 19.99 mS/cm ;

... to 199.9 mS/cm

Resolution:

0.001 µS/cm ; 0.01 µS/cm ;

0.1 µS/cm ; 1 µS/cm ;

5 µS/cm ; 0.01 mS/cm ;

0.1 mS/cm

Accuracy: ±1 % of full scale reading (±2 % >500 mS/cm)

Cell Constant: 0.01 ; 0.1 ; 1 ; 10

- Temperature

Range: -9.9 to 125 ºC

Resolution: 0.1 ºC

Accuracy: ±0.5 ºC

Sensor: Pt100 / Pt1000 (jumper selectable)

Compensation: Auto/manual (normalized at 25 ºC)

Coefficient: Ultrapure water or linear 0.00 to 10.00 %

- Set Point And Controller Functions

Set Point 1 (SP1)/ Set Point 2 (SP2):

... to 1.999 µS/cm or ... to 19.99 µS/cm or

... to 199.9 µS/cm or ... to 5000 µS/cm or

... to 19.99 mS/cm or ... to 199.9 mS/cm

Switching Conductivity Hysteresis: 0 to 10 % of full scale

Function (Switchable): P control (pulse length/pulse frequency); limit control

Adjustable Period With Pulse Length Controller: 0.5 to 20 sec

Adjustable Period With Pulse Frequency Controller: 60 to 120 pulse/min

Pickup/Dropout Delay: 0 to 2000 sec

Contact Outputs: 3 SPST relay

Switching Voltage/ Current/Power: Max. 250 VAC / max. 3 A / max. 600 VA

- Alarm Functions

Function (Switchable): Steady or fleet (pulse)

Wash Cycle: 0.1 to 199.9 hr

Wash Duration: 1 to 1999 sec

Pickup Delay: 0 to 2000 sec

Switching Voltage/Current/Power: Max. 250 VAC / max. 3 A / max. 600 VA

- Electrical Data And Connections

Transmitter Function: Two 0/4 to 20 mA scalable outputs for pH/ORP and temperature, galvanically isolated

CU 22 Function: 22 mA current output

Isolated Output Voltage: 12 V ±0.5 V (max. 50 mA)

Hold Function Switch: To freeze output current and deactivate control relays

Load: Max. 600 Ohm

Conductivity Input: 2-pin terminal

Connection Terminal: 5-pole, 17-pole terminal, detachable blocks

Power Supply

Input: 220 VAC (jumper selectable) ; 48 to 62 Hz ; max. 7 VA

Main Fuse: Slow-blow 250 V / 100 mA

Pollution Degree: 2

Operating Temperature Range: -10 to 50 ºC

Max. Relative Humidity: 80 % up to 31 ºC decreasing linearly to 50 % at 40 ºC

- Dimensions (WxHxD): 96 x 96 x 175 mm

Weight: 700 g (unit) / 800 g (packed)

Ingress Protection: IP54 (front panel)

Include: terminal blocks, gasket, threaded rods, catch, etc