SUPPRESSED O2 MODEL WITH STAINLESS STEEL EXTERIOR CABINET
CelCulture® Incubator: 240 L, IR Sensor, CO2 & O2 Control, ULPA, Moist Heat Decon, SS Cabinet, 230 VAC, 50/60 Hz
O2/T-SERIES (FOR SUPPRESSED O2 MODEL)
O2 Control System: Microcontroller PI
O2 Range, % O2: 1-18
O2 Accuracy, % O2: ± 0.1
O2 Sensor: Zirconia O2 sensor
Temperature Control Method: Direct heat & Air Jacket using Microcontroller PI
Ambient Temperature Range*: 18 to 32°C (64.4 to 89.6°F)
Temperature Range, °C*: Ambient +5 to 60
Temperature Uniformity, °C*: < ±0.5
Temperature Accuracy, °C*: < ±0.1
Temperature Recovery Time**: (after 30 seconds door opening, 98% from initial value) ≤6 minutes
CO2 Control System: Microcontroller PI
CO2 Range, % CO2: 0-19.5
CO2 Accuracy, % CO2: ±0.1
CO2 Sensor: Infrared (IR) Sensor
CO2 Recovery Time****: (after 30 seconds door opening, 98% from initial value) Standard Unit: ≤6 minutes; Suppressed O2 model: ≤10 minutes
HUMIDITY
Humidification Method: Humidity pan
Humidity Range, %RH (at 37 °C)******: 85-90
PHYSICAL CONSTRUCTION
Interior Volume: 240 L
External Dimensions (W x D x H): 750 x 770 x 900 mm
Internal Dimensions (W x D x H): 595 x 640 x 633 mm
Chamber Construction
Main Body: Electrogalvanized steel with Isocide™ antimicrobial coating (except CCL-SS models with stainless steel exterior)
Interior Material: Stainless steel, type 304 (except CCL-Cu models with copper interior chamber)
Number of Shelves: 4
Maximum Number of Shelves: 7
Electrical Configuration
110-130 VAC, 50/60 Hz: Full Load Amps: 13.4 A
Electrical Configuration
220-240 VAC, 50/60 Hz: Full Load Amps: 6.5 A
Net Weight: 121 kg
CONTAMINATION CONTROL
Contamination Control Methods
1, Main body is electro-galvanized steel with Isocide™ antimicrobial coating;
2, 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);
3, ULPA filter********
4, 0.2-micron inlet filter for gas inputs;
5, 1-micron air circulation filter
6, UV lamp (for CCL-UV models only)
7, Copper chamber interior (for CCL-Cu models only)
All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.
*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.
**For temperature not exceeding 37.2°C.
***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.
****For CO2 level not exceeding 5.2%.
*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.
****** For O2 level not lower than 4.8%.
*******Esco does not guarantee condensation-free chamber at humidity level higher than 90%.
********Not available for 50 L models.