IR SENSOR MODEL WITH INTEGRATED COOLING SYSTEM

CelCulture® Incubator 240 L: IR Sensor, CO2 Control, Moist Heat Decon, Peltier System, 230 VAC, 50/60 Hz


TEMPERATURE:

Temperature Control Method: Direct heat & Air Jacket using Microcontroller PI

Ambient Temperature Range: 18 to 32°C (64.4 to 89.6°F)

Temperature Range, °C: 8°C below ambient to 60°C

Temperature Uniformity*, °C:

Heating mode: < ±0.7

Cooling mode: < ±2.0

Temperature Accuracy*, °C: < ±0.1

Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value): ≤6 minutes


CO2:

CO2 Control System: Microcontroller PI

Range, % CO2: 0-19.5

Accuracy***, % CO2: ±0.1

Sensor: Infrared (IR) Sensor

Recovery Time**** (after 30 seconds door opening, 98% from initial value):

Standard Unit: ≤6 minutes

Suppressed O2 model: ≤10 minutes


HUMIDITY:

Humidity Method: Humidity Pan

Humidity Range, %RH (at 37°C)*******: 85-90


PHYSICAL CONSTRUCTION:

Interior Volume: 240 L

External Dimensions (W x D x H): 750 x 904 x 900 mm

Internal Dimensions (W x D x H): 595 x 640 x 633 mm

Chamber Construction: Main Body Electrogalvanized steel with Isocide™ antimicrobial coating

Interior Material: Stainless steel, type 304

Number of Shelves: 4

Maximum Number of Shelves: 7


ELECTRICAL CONFIGURATION:

110-130 VAC, 50/60 Hz: Full Load Amps: 13.4 A

220-240 VAC, 50/60 Hz: Full Load Amps: 6.5 A


Net Weight: 133 kg


CONTAMINATION CONTROL:

Contamination Control Methods:

1) Main body is electro-galvanized steel with Isocide™ antimicrobial coating;

2) 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);

3) ULPA filter********

4) 0.2-micron inlet filter for gas inputs;

5) 1-micron air circulation filter


All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.

*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.

**For temperature not exceeding 37.2°C.

***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.

****For CO2 level not exceeding 5.2%.

*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.

****** For O2 level not lower than 4.8%.

******* Esco does not guarantee condensation-free chamber at humidity level higher than 90%.

Catalog

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts