ESCO CCL-170T-9-NF-HHS CelCulture® CO₂ Incubator (170 L, 180°C HHS, 115 VAC 50/60 Hz)

ModelCCL-170T-9-NF-HHS
P/N2170309
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

SUPPRESSED O2 MODEL WITH STAINLESS STEEL CHAMBER (NO ULPA FILTER)

CelCulture® Incubator 170 L IR Sensor, CO2/O2 Control, 180°C HHS, 115 VAC 50/60 Hz, No ULPA Filter


O2:

O2 Control System: Microcontroller PI

O2 Control Range, % O2: 1-18

O2 Fluctuation, % O2: ± 0.3

O2 Sensor: Zirconia O2 Sensor


TEMPERATURE:

Temperature Control Method: Direct Heat and Air Jacket using Microcontroller PI

Ambient Temperature Range: 18 to 32°C (64.4 to 89.6°F)

Temperature Control Range, °C: Ambient +5 to 60

Temperature Uniformity, °C: Standard Unit: <± 0.35; Suppressed O2 model: <± 0.4

Temperature Fluctuation, °C: ±0.2

Temperature Recovery Time (after 30 seconds door opening, 98% from initial value): ≤5 minutes


CO2:

CO2 Control System: Microcontroller PI

CO2 Control Range, % CO2: 0-19.5

CO2 Fluctuation, % CO2: ± 0.2

CO2 Sensor: Infrared (IR) Sensor

CO2 Recovery Time (after 30 seconds door opening, 98% from initial value): At 5.0% CO2 by volume (Standard unit): ≤5 minutes; Suppressed O2 model: ≤8 mins.


HUMIDITY:

Humidification Method: Humidity pan

Humidity Range, %RH (at 37°C): 85-90


PHYSICAL CONSTRUCTION:

Interior Volume: 170 L

External Dimensions (W x D x H): 660 x 660 x 906 mm

Internal Dimensions (W x D x H): 505 x 535 x 633 mm

Net Weight: 101 kg

Chamber Construction: Main Body Electrogalvanized steel with Isocide™ antimicrobial coating; Interior Material Stainless steel, type 304

Number of Shelves: 4

Maximum Number of Shelves: 7

Electrical Configuration 110-130 VAC, 50/60 Hz

Full Load Amps: 10 A

Electrical Configuration 220-240 VAC, 50/60 Hz

Full Load Amps: 5 A


CONTAMINATION CONTROL

Contamination Control Methods

1) Main body is electrogalvanized steel with Isocide™ antimicrobial coating;

2) 180˚C high heat sterilization cycle;

3) ULPA filter (optional) - filter must be removed during sterilization cycle

4) 0.2 µm gas inlet filter

5) 1-micron air circulation filter


All data recorded were observed with unloaded chambers and under optimum factory setting of 22 ±3°C with room humidity of 30-60%.

*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.

**For temperature not exceeding 37.2°C.

***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.

****For CO2 level not exceeding 5.2%.

*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.

****** For O2 level not lower than 4.8%.

******* Esco does not guarantee condensation-free chamber at humidity level higher than 90%

CATALOG

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts