ESCO CCL-170T-8-UV-SS CelCulture® CO₂ Incubator (170 L, 230 VAC, 50/60 Hz, UV lamp)

ModelCCL-170T-8-UV-SS
P/N2170184
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

SUPPRESSED O2 MODEL WITH STAINLESS STEEL EXTERIOR CABINET

CelCulture® Incubator: 170L, IR Sensor, CO2 & O2 Control, ULPA, UV Lamp, Moist Heat Decon, SS Cabinet, 230 VAC, 50/60 Hz

O2/T-SERIES (FOR SUPPRESSED O2 MODEL)

O2 Control System: Microcontroller PI

O2 Range, % O2: 1-18

O2 Accuracy, % O2: ± 0.1

O2 Sensor: Zirconia O2 sensor

O2/T-SERIES (CHO MÔ HÌNH KIỂM SOÁT O2)

Temperature Control Method: Direct heat & Air Jacket using Microcontroller PI

Ambient Temperature Range*: 18 to 32°C (64.4 to 89.6°F)

Temperature Range, °C*: Ambient +5 to 60

Temperature Uniformity, °C*: < ±0.5

Temperature Accuracy, °C*: < ±0.1

Temperature Recovery Time**: (after 30 seconds door opening, 98% from initial value) ≤5 minutes

CO2 Control System: Microcontroller PI

CO2 Range, % CO2: 0-19.5

CO2 Accuracy, % CO2: ±0.1

CO2 Sensor: Infrared (IR) Sensor

CO2 Recovery Time****: (after 30 seconds door opening, 98% from initial value) Standard Unit: ≤5 minutes; Suppressed O2 model: ≤6 minutes

HUMIDITY

Humidification Method: Humidity pan

Humidity Range, %RH (at 37 °C)******: 85-90

PHYSICAL CONSTRUCTION

Interior Volume: 170 L

External Dimensions (W x D x H): 660 x 660 x 900 mm

Internal Dimensions (W x D x H): 505 x 535 x 633 mm

Chamber Construction

Main Body: Electrogalvanized steel with Isocide™ antimicrobial coating (except CCL-SS models with stainless steel exterior)

Interior Material: Stainless steel, type 304 (except CCL-Cu models with copper interior chamber)

Number of Shelves: 4

Maximum Number of Shelves: 7

Electrical Configuration

110-130 VAC, 50/60 Hz: Full Load Amps: 9.2 A

Electrical Configuration

220-240 VAC, 50/60 Hz: Full Load Amps: 4.2 A

Net Weight: 101 kg

CONTAMINATION CONTROL

Contamination Control Methods

1, Main body is electro-galvanized steel with Isocide™ antimicrobial coating;

2, 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);

3, ULPA filter********

4, 0.2-micron inlet filter for gas inputs;

5, 1-micron air circulation filter

6, UV lamp (for CCL-UV models only)

7, Copper chamber interior (for CCL-Cu models only)

All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.

*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.

**For temperature not exceeding 37.2°C.

***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.

****For CO2 level not exceeding 5.2%.

*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.

****** For O2 level not lower than 4.8%.

*******Esco does not guarantee condensation-free chamber at humidity level higher than 90%.

********Not available for 50 L models.