Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
SUPPRESSED O2 MODEL WITH STAINLESS STEEL CHAMBER
CelCulture® Incubator 170 L: IR Sensor, CO2 & O2 Control, ULPA, Moist Heat Decon, 230 VAC, 50/60 Hz
O2 (FOR MODELS WITH SUPPRESSED O2 CONTROL):
O2 Control System: Microcontroller PI
O2 Control Range, % O2: 1-18
O2 Fluctuation, % O2*****: ± 0.3
O2 Sensor: Zirconium dioxide sensor type
TEMPERATURE:
Temperature Control Method: Direct Heat and Air Jacket Using Microcontroller PI
Ambient Temperature Range*: 18 to 32°C (64.4 to 89.6°F)
Temperature Control Range, °C*: Ambient +5 to 60
Temperature Uniformity, °C*: Standard Unit: <± 0.35; Suppressed O2 model: <± 0.4
Temperature Fluctuation, °C*: <± 0.2
Temperature Recovery Time** (after 30 seconds door opening, 98% from initial value): ≤5 minutes
CO2:
CO2 Control System: Microcontroller PI
CO2 Control Range, % CO2: 0-19.5
CO2 Fluctuation, % CO2***: ± 0.2
CO2 Sensor: Infrared (IR) Sensor
CO2 Recovery Time**** (after 30 seconds door opening, 98% from initial value): Standard Unit: ≤5 minutes; Suppressed O2 model: ≤8 minutes
HUMIDITY:
Humidification Method: Humidity Pan
Humidity Range, %RH (at 37 °C)*******: 85-90
PHYSICAL CONSTRUCTION:
Interior Volume: 170 L
External Dimensions (W x D x H): 660 x 660 x 906 mm
Internal Dimensions (W x D x H): 505 x 535 x 633 mm
Chamber Construction: Main Body Electrogalvanized steel with Isocide™ antimicrobial coating
Interior Material: Stainless steel, type 304
Number of Shelves: 4
Maximum Number of Shelves: 7
Electrical Configuration 220-240 VAC, 50/60 Hz
Full Load Amps: 4.2 A
Net Weight: 101 kg
CONTAMINATION CONTROL
Contamination Control Methods
1) Main body is electro-galvanized steel with Isocide™ antimicrobial coating;
2) 90˚C moist heat OVERNIGHT decontamination cycle (HPA validated);
3) ULPA filter
4) 0.2-micron inlet filter for gas inputs;
5) 1-micron air circulation filter
All data recorded is specified for standard models with unloaded chambers and tested under optimum factory setting conditions of 23°C and 60% ambient humidity.
*Results are achieved when tested at 37°C as set point. Results may vary if set point changes and calibration is needed.
**For temperature not exceeding 37.2°C.
***Results are achieved when tested at 5% CO2 as set point. Results may vary if set point changes and calibration is needed.
****For CO2 level not exceeding 5.2%.
*****Results are achieved when tested at 5% O2 as set point. Results may vary if set point changes and calibration is needed.
****** For O2 level not lower than 4.8%.
******* Esco does not guarantee condensation-free chamber at humidity level higher than 90%.