Temperature measuring range: -50℃~90℃ / -58℉~194℉ (only when sensor calibration is set as 0)
Temperature control range: -50℃~85℃ or -58℉~185℉
Temperature resolution: 0.1℃ / 1℉
Temperature accuracy: ±1℃(-50℃~50℃), ±2℃(others)
Power voltage: 12VAC/115VAC/220VAC/230VAC
Overall power consumption: ≤ 5W (Max)
microUPS interface
Vertical protection grade (front panel): IP65; provided with watertight structure and backside drip-proof cover.
Operating/working temperature: 0℃~55℃
Storage environment: Temperature: -25℃~75℃; Humidity: 20%~85% (non-condensing)