Weight: 227 g
Accuracy: ± 0.2 %
Accuracy Note: ± .20% FS (includes non-linearity, hysteresis and non-repeatability)
Output Detail: 4 to 20 mA
Output Signal: Current
Pressure Type: Gauge
Pressure, Max: 30 psi
Pressure, Min: 0 psi
Response Time: ≤ 10 ms
Burst Pressure: 50 psi Maximum
Supply Voltage: 9 to 30 Vdc
Clamping Effect: Zero and Span Shift: ± 0.15% FS
Loop Resistance: 800 Ω
Number of Wires: 2
Span Adjustment: ± 0.5 mA, Non-Interactive
Thermal Effects: Zero and Span Shift: ± 2.0% FS/100°F
Materials, Wetted: 316L Stainless Steel
Relative Humidity: 10 to 90% RH, Non-Condensing
Supply Power Type: DC
Media Compatibility: Alcohols, Argon, Compatible Gases, Compatible Liquids, Nitrogen, Oils, Water
Electrical Connection: 1/2 NPT male Conduit with Cable
Process Connection Size: 2 in
Process Connection Type: Tri-Clamp
Operating Temperature, Max: 260 °F
Operating Temperature, Min: -40 °F
Compensated Temperature, Max: 180 °F
Compensated Temperature, Min: 20 °F
Zero Setting Adjustable Range: ± 0.5 mA, Non-Interactive