Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

Dimensions (W x H x D): 48 x 130 x 44 mm (1.85 x 5.12 x 1.73 in)
Weight: 220 – 250 g (8 - 9 oz)
Ambient conditions
Temperature: -20 to 50 C (-4 to 122 F)
Pressure: 700 to 1,300 mbar (20.7 to 38.4 inch Hg)
Relative humidity: 10 to 95 % r.h.
Protection class: IP67
Alarms
Visual: 360°
Audible: Multi-tone > 90 dB at 30 cm (12 in)
Vibration
Operating times: > 12 h with alkaline and NiMH, > 13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline batteries
Charging times: < 4 h
Data logger: Retrievable using an infrared interface > 1000 h with 4 gases at a recording interval of 1 value per minute
Pump operation: Maximum hose length 45 m (147 ft)
Approvals
ATEX:
I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb,
II 2G Ex d ia IIC T4/T3 Gb
Performance approval to:
EN 50104(2002) + A1 (2004); O2
EN 45544; CO & H2S
EN 60079-29-1:2007; Methane to nonane
EN 50271:2001; Software and documentation
CSA (Canada & USA)
Class I Div. 1 Group A, B, C, D; T.-Code T4/T3
A/Ex ia IIC T3/Ga
A/Ex d ia IIC T4/T3/Gb
IECEx:
Ex ia I Ma
Ex ia IIC T3 Ga
Ex d ia I Mb
Ex d ia IIC T4/T3 Gb
CE mark: Electromagnetic Compatibility (Directive 2004/108/EC); (Directive 94/9/EC)
MED: Marine Equipment Directive (Directive 96/98/EC)
MSHA: Permissible Gas Detector