Measured value: Temperature, Relative humidity, Counted values (Dew point…), CO2, Atmospheric pressure, Current, Voltage, Two-state signal, Pulses
Temperature sensor - external probe PT1000:
Measuring range: -200 to +600 °C
Accuracy: ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C
Resolution: 0.1 °C
Temperature + humidity sensor - external probe T+RH DIGI:
Measuring range: according to the connected probe Digi/M
Accuracy: according to the connected probe Digi/M
Resolution: 0.1 °C
Dew point:
Measuring range: according to the connected probe Digi/M
Accuracy: according to the connected probe Digi/M
Resolution: 0.1 °C
Atmospheric pressure sensor:
Measuring range: 700 hPa to 1100 hPa
Accuracy: ±1.3 hPa at 23 °C
Resolution: 0.1 hPa
CO2 SENSOR:
Measuring range: 0 to 2 000 ppm
Accuracy: 50 ppm + 2 % of the Measured value at 23 °C a 1013 hPa
Resolution: 1 ppm
DC voltage:
Measuring range: 0 to 10 V
Accuracy: ±10 mV
Resolution: better than 100 µV
DC CURRENT:
Measuring range: 0 to 20 mA
Accuracy: ±20 µA
Resolution: better than 0.1 µA
BINARY SIGNAL:
Input voltage for level “switched on”: <0.4 V/> 2 V
Minimum/maximum input voltage: 0 V/+30 V DC
Impedance of the “switched on”: < 10 kOhm/> 300 kOhm
Counter input:
Range of counter: 24 bit (16 777 215) the counter overflow can be allowed
Maximum input frequency: 200 Hz
Operating temperature: -10 to +60 °C
Channels: internal Atmospheric pressure sensor a CO2, 2x external temperature probe or connectable temperature+humidity probe, 2x binary, counter, voltage and current input
Counted values: Dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
Recording interval: 1s to 24 hours
Display and alarm refresh: each 10 s
Recording mode: noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Available temperature units: degrees Celsius, degrees Fahrenheit
Communication interface: Ethernet, USB, RS232
Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
Alarm protocols E-Mail
Power: AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)
Protection class: IP20
Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
Weight (including batteries): approx. 380 g
Included in delivery:
M1323
Instruction Manual
Traceable Calibration Certificate
3x Rechargeable Battery AA
Power Supply
USB Cable
Wall Holder
FREE FULL VERSION Analytical Software COMET Vision
EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY