Measurement components and ranges: 0-25.0% O2
Detection principle: Tunable Semiconductor Laser Diode. Absorption Spectrometry (TDLAS)
System power supply: DC24V 10W
Alarm: 1-way alarm output(analyzer failure alarm)
Relay contact capacity: 24VDC,0.2A
Signal output: A group of 4-20 mA outputs correspond to O2
Environmental temperature: 0-45°C Environmental humidity:Less than 80% RH
Intake pressure: Steam injection sampling at negative and micro-positive pressures
Sample flow rate: 4-6L/min
Inlet and outlet interfaces: Φ25Clamp locking mode
Analyzer life: More than 5 years (normal use)
Installation mode: Base expansion screw fixation
Circuit structure: Applied in low explosion-proof or non-explosion-proof occasions
System warranty period: 12 months
Calibration of analyzer: It is suggested that one calibration should be carried out once a year,and one standard gas and high purity nitrogen, should be prepared for each calibration zero point and range point.
System size: D*W*H=1530mm*420mm*2280mm
Housing dimensions: D*W*H=3000mm*3000mm*3000mm
Installation dimensions: D*W=1466mm*366mm (expanding screw)
Packing box: Wooden box packing
System weight: About 300 Kg