Chang AI CI-PC95-2 Explosion-proof trace oxygen analyzer (0~10/100/1000ppm/1%/25.00% O2)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Sensor: Fuel cell oxygen sensor

Measure range: 0~10/100/1000ppm/1%/25.00% O2

Accuracy:

0.01~9.99ppm O2:±5%FS

10.0~99.9ppm O2:±3%FS

100~1000ppm O2:±2%FS

Repeatability:

0.01~9.99ppm O2:±2.5%FS

10.0~99.9ppm O2:±1.5%FS

100~1000ppm O2:±1%FS

Stability:

0.01~9.99ppm O2:±2.5%FS/7d

10.0~99.9ppm O2:±1.5%FS/7d

100~1000ppm O2:±1%FS/7d

Response time: T90<60s(25°C)

Explosionproof grade: Exd || CT6

Protection level: IP65

Calibration cycle: one year (recommended)

Power supply: 24VDC

Analyzer power: <15VA

consumption: RS485/RS232

Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/ 0-10V/1-5V (You can set the mode freely).

The load: less than 500 Ω

Switch output: Alarm value:1; Relay contact point capacity:24V DC,0.2A

Environment temperature: -10~+45°C Environment Humidity:<90%RH

Sample gas pressure: atmospheric conditions±10% (Gas outlet should be atmospheric conditions)

Sample flow rate: 1.5~2L/min

Inlet and outlet: 1/4-inch NPT internal thread,standard 6.5 hose joint

Sensor life: more than 2 years (normal use)

Instrument life: more than 5 years (normal use)

Weight: Net weight 2.0 kg

Installation: wall-mounted


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.